A new control approach to improve the overall performance of DFIG-based WECS
- Authors: Khamaira, Mahmoud , Abu-Siada, Ahmed , Islam, Syed , Masoum, Mohammad
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 24th Australasian Universities Power Engineering Conference, AUPEC 2014; Perth, Australia; 28th September-1st October 2014 p. 1-5
- Full Text: false
- Reviewed:
- Description: Doubly Fed Induction Generators (DFIGs) are currently extensively used in variable speed wind power plants due to their superior advantages that include reduced converter rating, low cost, reduced losses, easy implementation of power factor correction schemes, variable speed operation and four quadrants active and reactive power control capabilities. On the other hand, DFIG sensitivity to grid disturbances, especially for voltage sags represents the main disadvantage of the equipment. In this paper, a coil is proposed to be integrated within the DFIG converters to improve the overall performance of a DFIG-based wind energy conversion system (WECS). A proportional integral (PI) controller to control the charging and discharging of the coil is introduced. Simulation results reveal the effectiveness of the proposed topology in improving the overall performance of the WECS under study.
A new topology for doubly fed induction generator to improve the overall performance of wind energy conversion system
- Authors: Khamaira, Mahmoud , Abu-Siada, Ahmed , Islam, Syed , Masoum, Mohammad
- Date: 2014
- Type: Text , Journal article
- Relation: Elixir International Journal: Electrical Engineering Vol. 73, no. (2014), p. 26432-26435
- Full Text:
- Reviewed:
- Description: Doubly Fed Induction Generators (DFIGs) are currently extensively used in variable speed wind power plants due to their superior advantages that include reduced converter rating, low cost, reduced losses, easy implementation of power factor correction schemes, variable speed operation and four quadrants active and reactive power control capabilities. On the other hand, DFIG sensitivity to grid disturbances, especially for voltage sags represents the main disadvantage of the equipment. In this paper, a coil is proposed to be integrated within the DFIG converters to improve the overall performance of a DFIGbased wind energy conversion system (WECS). The charging and discharging of the coil are controlled by controlling the duty cycle of the switches of the dc-dc chopper. Simulation results reveal the effectiveness of the proposed topology in improving the overall performance of the WECS system under study.
Application of SMES unit to improve the overall performance of DFIG-based WECS
- Authors: Khamaira, Mahmoud , Abu-Siada, Ahmed , Islam, Syed , Masoum, Mohammad
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 2014 IEEE Power and Energy Society General Meeting; National Harbor, United States; 27th-31st July 2014 Vol. 2014, p. 1-5
- Full Text: false
- Reviewed:
- Description: Doubly Fed Induction Generators (DFIGs) are nowadays extensively used in variable speed wind power plants due to their advantages that include reduced converter rating, low cost, reduced losses with an improved efficiency, easy implementation of power factor correction schemes, variable speed operation and four quadrants active and reactive power control capabilities. On the other hand, DFIG sensitivity to grid disturbances, especially for the voltage dip represents the main disadvantage of the equipment. This paper presents the application of superconducting magnetic energy storage (SMES) unit to improve the overall performance of a DFIG-based wind energy conversion systems (WECS). Two control approaches namely; hysteresis current controller (HCC) along with proportional integral (PI) controller and a fuzzy logic (FL) controller for the SMES unit are presented and compared. Various grid codes are used to examine the capability of the two proposed controllers to improve the low voltage ride through (LVRT) capability of the DFIG to maintain the wind turbine connection to the grid through fault durations.
- Description: IEEE Power and Energy Society General Meeting