Application of digital image processing to diagnose transformer winding deformation using FRA polar plot
- Authors: Aljohani, Omar , Abu-Siada, Ahmed , Islam, Syed
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 2014 International Conference on Condition Monitoring and Diagnosis, CMD 2014; Jeju, Korea; 21st September 2014
- Full Text: false
- Reviewed:
- Description: Digital image processing (DIP) technique has been growing rapidly as an essential tool to interpret various image features for many applications of science and engineering. Condition monitoring and diagnosis are considered the main areas that relay on DIP. Frequency response analysis (FRA) technique has become a popular and reliable diagnostic tool in detecting various winding deformations within power transformers. However, interpretation of FRA signatures still requires high expertise because of its reliance on graphical analysis. This paper presents a new technique for the interpretation of transformers FRA signatures. The proposed technique relies on incorporating both magnitude and angle of the FRA signature in one polar plot, which is manipulated to extract some unique features using DIP techniques. The proposed technique can assess in identifying and quantifying various winding deformation within power transformers. The proposed technique is easy to implement in any frequency response analyser.
Condition assessment of power transformer bushing using SFRA and DGA as auxiliary tools
- Authors: Mohseni, Bahar , Hashemnia, Naser , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 IEEE International Conference on Power System Technology, POWERCON 2016; Wollongong, Australia; 28th September-1st October 2016 p. 1-4
- Full Text: false
- Reviewed:
- Description: Dielectric insulation of a transformer bushing deteriorates as a function of temperature, oxidation, and moisture. This causes accelerated aging of oil and cellulosic solid insulation, generating fault gases within bushing oil and eventual permanent failure. To prevent such failures, effective analyses and diagnoses need to be investigated. Dissolved Gas Analysis (DGA) can give the indication of internal abnormalities inside the transformer bushing. In addition, Frequency response analysis (FRA) is a widely accepted tool for mechanical deformation diagnosis within power transformers. Although a large number of studies have been conducted on the detection of transformer winding deformation by FRA technique, the impact of bushing faults on the transformer FRA signature has not been sufficiently investigated. It is the goal of this paper to propose precise simulation as well as practical analyses demonstrating the impact of bushing faults on the FRA signature. A real transformer bushing geometry is modelled through 3D finite element analysis (FEM) on which different bushing faults are emulated. To verify the derived simulation results, DGA of transformer oil as well as FRA are performed on a three-phase, 132 kV, 315 MVA power transformer. It can be observed clearly from the results, that bushing faults have an impact on the FRA signature and DGA of the power transformer.
Detection of power transformer disk space variation and core deformation using frequency response analysis
- Authors: Hashemnia, Naser , Abu-Siada, Ahmed , Islam, Syed
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 2014 International Conference on Condition Monitoring and Diagnosis, CMD 2014; Jeju, Korea; 21st September 2014
- Full Text: false
- Reviewed:
- Description: Frequency response analysis (FRA) has become a widely accepted tool to detect power transformer winding deformation due to the development of FRA test equipment. Because FRA relies on graphical analysis, interpretation of its signature is a very specialized area that calls for skilled personnel, as so far, there is no reliable standard code for FRA signature classification and quantification. Many researchers investigated the impact of various mechanical winding deformations on the transformer FRA signature by changing particular electrical parameters of the transformer equivalent electrical circuit. None of them however, investigated the impact of physical fault levels on the transformer FRA signature as it is very difficult to implement faults within real transformer without damaging it. In this paper, the physical geometrical dimension of a power transformer is simulated using 3D finite element analysis to emulate the real transformer operation. Physical core deformation and disk space variation are simulated and the impact of each fault on the transformer FRA signature is investigated.
Image processing-based on-line technique to detect power transformer winding faults
- Authors: Abu-Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 39th Annual Conference of the IEEE Industrial Electronics Society, IECON 2013; Vienna, Austria; 10th-14th November 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: Frequency Response Analysis (FRA) has been growing in popularity in recent times as a tool to detect mechanical deformation within power transformers. To conduct the test, the transformer has to be taken out of service which may cause interruption to the electricity grid. Moreover, because FRA relies on graphical analysis, it calls for an expert person to analyse the results as so far, there is no standard code for FRA interpretation worldwide. In this paper an online technique is introduced to detect the internal faults within a power transformer by constructing the voltage-current (V-I) locus diagram to provide a current state of the transformer health condition. The technique does not call for any special equipment as it uses the existing metering devices attached to any power transformer to monitor the input voltage, output voltage and the input current at the power frequency and hence online monitoring can be realised. Various types of faults have been simulated to assess its impact on the proposed locus. A Matlab code based on digital image processing is developed to calculate any deviation of the V-I locus with respect to the reference one and to identify the type of fault.
Impact of axial displacement on power transformer FRA signature
- Authors: Hashemnia, Naser , Abu-Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 IEEE Power and Energy Society General Meeting, PES 2013; Vancouver, Canada; 21st-25th July 2013 p. 1-4
- Full Text:
- Reviewed:
- Description: Frequency response analysis (FRA) is gaining global popularity in detecting power transformer winding movement due to the development of FRA test equipment. However, because FRA relies on graphical analysis, interpretation of its signatures is still a very specialized area that calls for skillful personnel to detect the sort and likely place of the fault as so far, there is no reliable standard code for FRA signature classification and quantification. This paper investigates the impact of transformer winding axial displacement on its FRA signature as a step toward the establishment of reliable codes for FRA interpretation. In this context a detailed model for a singlephase transformer is simulated using 3D finite element analysis to emulate a close to real transformer. The impact of axial displacement on the electrical distributed parameters model that are calculated based on the transformer physical dimension is examined to investigate how model’s parameters including inductance and capacitance matrices change when axial displacement takes place within a power transformer.
Impact of buckling deformation on the FRA signature of power transformer
- Authors: Amini, Arman , Das, Narottam , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 Australasian Universities Power Engineering Conference, AUPEC 2013; Hobart, Australia; 29th September-3rd October 2013 p. 1-4
- Full Text: false
- Reviewed:
- Description: Power transformer is an important asset within the electrical power system network. Frequency Response Analysis (FRA) has been developing in popularity in recent years as a tool to detect mechanical deformation of power transformers winding. Since the FRA has been relying on graphical analysis, it calls for an expert person to analyze the results to detect the type of the fault and its location. There are no reliable guidelines for FRA signature in the event that a failure occurs in service and the impact can be far reaching. The concept of FRA has been successfully used as a diagnostic technique to detect the winding deformation, core and clamping structure for the power transformers. This paper investigated the impact of the forced and free winding buckling based on the variation of the electrical parameters to show how these faults vary the FRA signature.
SOAP based assistive care loop using wireless sensor networks
- Authors: Balasubramanian, Venki , Hoang, Doan , Ahmad, N. F.
- Date: 2008
- Type: Text , Conference proceedings
- Relation: 2008 IEEE International Symposium on IT in Medicine and Education, ITME 2008; Xiamen; China; 12th-14th December 2008 published in Proceedings of 2008 IEEE International Symposium on IT in Medicine and Education, ITME 2008 p. 409-414
- Full Text: false
- Reviewed:
- Description: There is a growing trend towards in-house health monitoring system. It is now feasible to place a Personal Digital Assistant (PDA) or smart phone in the hands of care-delivery staff and the patients regardless of where they are located or what their duties might be. In such instance, the staff would be able to access records and communicate with patients in a flexible and cost effective way. This paper proposes an Active Care Loop Framework (ACLF). The strength of our ACLF is to monitor disease over longer period of time and to consult patient who are then able to discuss their conditions with the care staff. Where patients need emergency intervention, an assistive health monitoring system can provide a direct communication channel to summon assistance and to enable with managing the situation until the assistance arrives. With a regular schedule of monitoring and consultation, the assistive ACLF has the capacity to forestall and manage non-critical situations and therefore the system can be deployed to minimize the rate and costs of hospitalizations. © 2008 Crown.
- Description: Proceedings of 2008 IEEE International Symposium on IT in Medicine and Education, ITME 2008