Impact of distributed rooftop photovoltaic systems on short-circuit faults in the supplying low voltage networks
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2017
- Type: Text , Journal article
- Relation: Electric Power Components and Systems Vol. 45, no. 20 (2017), p. 2257-2274
- Full Text:
- Reviewed:
- Description: This article evaluates the effect of randomly distributed, residential single-phase rooftop photovoltaic systems in the low voltage residential networks, during short-circuit faults on the overhead lines. The important parameters such as the fault current, the current sensed at the distribution transformer secondary, and the voltage profile along the feeder during the fault are examined. A sensitivity analysis is carried out in which the rating and location of the photovoltaic systems in the feeder, as well as the fault location and type, are the considered variables. Moreover, to demonstrate the effect of multiple photovoltaic systems with different ratings and penetration levels when distributed unequally among three phases of the network, a stochastic analysis is carried out. The article summarizes the outcomes of these two analyses to provide a better understanding of the impact of single-phase rooftop photovoltaic systems on the residential feeders during short-circuit faults.
Disconnection of single-phase rooftop PVs after short-circuit faults in residential feeders
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2016
- Type: Text , Journal article
- Relation: Australian Journal of Electrical and Electronics Engineering Vol. 13, no. 2 (2016), p. 151-165
- Full Text:
- Reviewed:
- Description: This paper presents an analysis on the disconnection time of single-phase rooftop photovoltaic systems (PVs), located in a three-phase four-wire low voltage distribution feeder, after a single-phase and a three-phase short-circuit fault on the low-voltage feeder. The paper aims to evaluate and discuss the disconnection time and disconnection sequence of PVs in a network with 100% PV penetration level to evaluate the islanding issues that are related to the safety of people and the damage of electrical apparatus. The impact of different parameters such as the location of the fault, impedance of the fault and the ratio of PVs generation capacity to the load demand are contemplated in the analysis. Furthermore, the influence of the network earthing in the form of multiple earthed neutral and non-effectively grounded systems are evaluated on the PVs disconnection time. This research intends to figure out the conditions under which the PVs in the feeder may fail to disconnect after a single-phase or three-phase fault and continue to feed the fault.
Disconnection time and sequence of rooftop PVs under short-circuit faults in low voltage networks
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: North American Power Symposium, NAPS 2015; Charlotte, United States; 4th-6th October 2015 p. 1-6
- Full Text:
- Reviewed:
- Description: This paper presents an analysis on the disconnection time of single-phase rooftop PVs, located in a three-phase four-wire low voltage distribution feeder after a line-to-ground short-circuit fault on the low voltage feeder. The paper aims to evaluate and discuss the disconnection time and sequence of PVs in a network with 100% PV penetration level. The impact of different parameters such as the location of the fault, impedance of the fault and the ratio of PVs generation capacity to the load demand are considered. Furthermore, the effect of the system earthing in the form of multiple earthed neutral and non-effectively grounded systems are evaluated on the PVs disconnection time. The analyses intend to figure out the conditions under which the PVs in the feeder may fail to disconnect after a line-to-ground fault and keep feeding the fault. The analyses are carried out in PSCAD/EMTDC software.
Contributions of single–phase rooftop PVs on short circuits faults in residential feeders
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 24th Australasian Universities Power Engineering Conference, AUPEC 2014; Perth, Australia; 28th September-1st October 2014 p. 1-6
- Full Text:
- Reviewed:
- Description: Sensitivity analysis results are presented to investigate the presence of single–phase rooftop Photovoltaic Cells (PV) in low voltage residential feeders, during short circuits in the overhead lines. The PV rating and location in the feeder and the fault location are considered as the variables of the sensitivity analysis. The single–phase faults are the main focus of this paper and the PV effect on fault current, current in distribution transformer secondary and the voltage at each bus of the feeder are investigated, during fault. Furthermore, to analyze the bus voltages and fault current in the presence of multiple PVs, each with different rating and location, a stochastic analysis is carried out to investigate the expected probability density function of these parameters, considering the uncertainties of PV rating and location as well as fault location.