Assessing transformer oil quality using deep convolutional networks
- Alam, Mohammad, Karmakar, Gour, Islam, Syed, Kamruzzaman, Joarder, Chetty, Madhu, Lim, Suryani, Appuhamillage, Gayan, Chattopadhyay, Gopi, Wilcox, Steve, Verheyen, Vincent
- Authors: Alam, Mohammad , Karmakar, Gour , Islam, Syed , Kamruzzaman, Joarder , Chetty, Madhu , Lim, Suryani , Appuhamillage, Gayan , Chattopadhyay, Gopi , Wilcox, Steve , Verheyen, Vincent
- Date: 2019
- Type: Text , Conference proceedings , Conference paper
- Relation: 29th Australasian Universities Power Engineering Conference, AUPEC 2019
- Full Text:
- Reviewed:
- Description: Electrical power grids comprise a significantly large number of transformers that interconnect power generation, transmission and distribution. These transformers having different MVA ratings are critical assets that require proper maintenance to provide long and uninterrupted electrical service. The mineral oil, an essential component of any transformer, not only provides cooling but also acts as an insulating medium within the transformer. The quality and the key dissolved properties of insulating mineral oil for the transformer are critical with its proper and reliable operation. However, traditional chemical diagnostic methods are expensive and time-consuming. A transformer oil image analysis approach, based on the entropy value of oil, which is inexpensive, effective and quick. However, the inability of entropy to estimate the vital transformer oil properties such as equivalent age, Neutralization Number (NN), dissipation factor (tanδ) and power factor (PF); and many intuitively derived constants usage limit its estimation accuracy. To address this issue, in this paper, we introduce an innovative transformer oil analysis using two deep convolutional learning techniques such as Convolutional Neural Network (ConvNet) and Residual Neural Network (ResNet). These two deep neural networks are chosen for this project as they have superior performance in computer vision. After estimating the equivalent aging year of transformer oil from its image by our proposed method, NN, tanδ and PF are computed using that estimated age. Our deep learning based techniques can accurately predict the transformer oil equivalent age, leading to calculate NN, tanδ and PF more accurately. The root means square error of estimated equivalent age produced by entropy, ConvNet and ResNet based methods are 0.718, 0.122 and 0.065, respectively. ConvNet and ResNet based methods have reduced the error of the oil age estimation by 83% and 91%, respectively compared to that of the entropy method. Our proposed oil image analysis can calculate the equivalent age that is very close to the actual age for all images used in the experiment. © 2019 IEEE.
- Description: E1
- Authors: Alam, Mohammad , Karmakar, Gour , Islam, Syed , Kamruzzaman, Joarder , Chetty, Madhu , Lim, Suryani , Appuhamillage, Gayan , Chattopadhyay, Gopi , Wilcox, Steve , Verheyen, Vincent
- Date: 2019
- Type: Text , Conference proceedings , Conference paper
- Relation: 29th Australasian Universities Power Engineering Conference, AUPEC 2019
- Full Text:
- Reviewed:
- Description: Electrical power grids comprise a significantly large number of transformers that interconnect power generation, transmission and distribution. These transformers having different MVA ratings are critical assets that require proper maintenance to provide long and uninterrupted electrical service. The mineral oil, an essential component of any transformer, not only provides cooling but also acts as an insulating medium within the transformer. The quality and the key dissolved properties of insulating mineral oil for the transformer are critical with its proper and reliable operation. However, traditional chemical diagnostic methods are expensive and time-consuming. A transformer oil image analysis approach, based on the entropy value of oil, which is inexpensive, effective and quick. However, the inability of entropy to estimate the vital transformer oil properties such as equivalent age, Neutralization Number (NN), dissipation factor (tanδ) and power factor (PF); and many intuitively derived constants usage limit its estimation accuracy. To address this issue, in this paper, we introduce an innovative transformer oil analysis using two deep convolutional learning techniques such as Convolutional Neural Network (ConvNet) and Residual Neural Network (ResNet). These two deep neural networks are chosen for this project as they have superior performance in computer vision. After estimating the equivalent aging year of transformer oil from its image by our proposed method, NN, tanδ and PF are computed using that estimated age. Our deep learning based techniques can accurately predict the transformer oil equivalent age, leading to calculate NN, tanδ and PF more accurately. The root means square error of estimated equivalent age produced by entropy, ConvNet and ResNet based methods are 0.718, 0.122 and 0.065, respectively. ConvNet and ResNet based methods have reduced the error of the oil age estimation by 83% and 91%, respectively compared to that of the entropy method. Our proposed oil image analysis can calculate the equivalent age that is very close to the actual age for all images used in the experiment. © 2019 IEEE.
- Description: E1
Investigation of microgrid instability caused by time delay
- Aghanoori, Navid, Masoum, Mohammad, Islam, Syed, Nethery, Steven
- Authors: Aghanoori, Navid , Masoum, Mohammad , Islam, Syed , Nethery, Steven
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 10th International Conference on Electrical and Electronics Engineering, ELECO 2017; Bursa, Turkey; 29th-2nd December 2017 Vol. 2018, p. 105-110
- Full Text:
- Reviewed:
- Description: This paper investigates the impact of time delay in the control of a grid-connected microgrid with renewable energy resources. The considered microgrid has a critical load that needs to be powered and protected in the event of grid voltage disturbance while the microgrid maintains connection to the grid. Three case studies are performed considering three different time delays to indicate the advantages of fast communication system in the performance of renewable microgrids. Detailed simulation results illustrate that the proposed communication system using IEC 61850 substation automation standard provides better voltage and current quality to the critical local load with larger phase and gain margins while keeping the microgid connected to main grid.
- Authors: Aghanoori, Navid , Masoum, Mohammad , Islam, Syed , Nethery, Steven
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 10th International Conference on Electrical and Electronics Engineering, ELECO 2017; Bursa, Turkey; 29th-2nd December 2017 Vol. 2018, p. 105-110
- Full Text:
- Reviewed:
- Description: This paper investigates the impact of time delay in the control of a grid-connected microgrid with renewable energy resources. The considered microgrid has a critical load that needs to be powered and protected in the event of grid voltage disturbance while the microgrid maintains connection to the grid. Three case studies are performed considering three different time delays to indicate the advantages of fast communication system in the performance of renewable microgrids. Detailed simulation results illustrate that the proposed communication system using IEC 61850 substation automation standard provides better voltage and current quality to the critical local load with larger phase and gain margins while keeping the microgid connected to main grid.
Master control unit based power exchange strategy for interconnected microgrids
- Batool, Munira, Islam, Syed, Shahnia, Farhad
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 2017 Australasian Universities Power Engineering Conference, AUPEC 2017; Melbourne, Australia; 19th-22nd November 2017 Vol. 2017, p. 1-6
- Full Text:
- Reviewed:
- Description: Large remote area networks normally have self-suffi-cient electricity systems. These systems also rely on non-dispatchable DGs (N-DGs) for overall reduction in cost of electricity production. It is a fact that uncertainties included in the nature of N-DGs as well as load demand can cause cost burden on islanded microgrids (MGs). This paper proposes development of power exchange strategy for an interconnected MGs (IMG) system as part of large remote area network with optimized controls of dispatchable (D-DGs) which are members of master control unit (MCU). MCU analysis includes equal cost increment principle to give idea about the amount of power exchange which could take place with neighbor MGs in case of overloading situation. Sudden changes in N-DGs and load are defined as interruptions and are part of analysis too. Optimization problem is formulated on the basis of MCU adjustment for overloading or under loading situation and suitability of support MG (S-MG) in IMG system for power exchange along with key features of low cost and minimum technical impacts. Mixed integer linear programming (MILP) technique is applied to solve the formulated problem. The impact of proposed strategy is assessed by numerical analysis in MATLAB programming under stochastic environment.
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 2017 Australasian Universities Power Engineering Conference, AUPEC 2017; Melbourne, Australia; 19th-22nd November 2017 Vol. 2017, p. 1-6
- Full Text:
- Reviewed:
- Description: Large remote area networks normally have self-suffi-cient electricity systems. These systems also rely on non-dispatchable DGs (N-DGs) for overall reduction in cost of electricity production. It is a fact that uncertainties included in the nature of N-DGs as well as load demand can cause cost burden on islanded microgrids (MGs). This paper proposes development of power exchange strategy for an interconnected MGs (IMG) system as part of large remote area network with optimized controls of dispatchable (D-DGs) which are members of master control unit (MCU). MCU analysis includes equal cost increment principle to give idea about the amount of power exchange which could take place with neighbor MGs in case of overloading situation. Sudden changes in N-DGs and load are defined as interruptions and are part of analysis too. Optimization problem is formulated on the basis of MCU adjustment for overloading or under loading situation and suitability of support MG (S-MG) in IMG system for power exchange along with key features of low cost and minimum technical impacts. Mixed integer linear programming (MILP) technique is applied to solve the formulated problem. The impact of proposed strategy is assessed by numerical analysis in MATLAB programming under stochastic environment.
Power transaction management amongst coupled microgrids in remote areas
- Batool, Munira, Islam, Syed, Shahnia, Farhad
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 7th IEEE Innovative Smart Grid Technologies - Asia, ISGT-Asia 2017;Auckland, New Zealand; 4th-7th December 2017 p. 1-6
- Full Text:
- Reviewed:
- Description: Large remote areas normally have isolated and self-sufficient electricity supply systems, often referred to as microgrids. These systems also rely on a mix of dispatchable and non-dispatcha- ble distributed energy resources to reduce the overall cost of electricity production. Emergencies such as shortfalls, overloading, and faults can cause problems in the operation of these remote area microgrids. This paper presents a power transaction management scheme amongst a few such microgrids when they are coupled provisionally during emergencies. By definition, power transaction is an instance of buying and selling of electricity amongst problem and healthy microgrids. The developed technique aims to define the suitable power generation from all dispatchable sources and regulate the power transaction amongst the coupled microgrids. To this end, an optimization problem is formulated that aims to define the above parameters while minimizing the costs and technical impacts. A mixed- integer linear programming technique is used to solve the formulated problem. The performance of the proposed management strategy is evaluated by numerical analysis in MATLAB.
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 7th IEEE Innovative Smart Grid Technologies - Asia, ISGT-Asia 2017;Auckland, New Zealand; 4th-7th December 2017 p. 1-6
- Full Text:
- Reviewed:
- Description: Large remote areas normally have isolated and self-sufficient electricity supply systems, often referred to as microgrids. These systems also rely on a mix of dispatchable and non-dispatcha- ble distributed energy resources to reduce the overall cost of electricity production. Emergencies such as shortfalls, overloading, and faults can cause problems in the operation of these remote area microgrids. This paper presents a power transaction management scheme amongst a few such microgrids when they are coupled provisionally during emergencies. By definition, power transaction is an instance of buying and selling of electricity amongst problem and healthy microgrids. The developed technique aims to define the suitable power generation from all dispatchable sources and regulate the power transaction amongst the coupled microgrids. To this end, an optimization problem is formulated that aims to define the above parameters while minimizing the costs and technical impacts. A mixed- integer linear programming technique is used to solve the formulated problem. The performance of the proposed management strategy is evaluated by numerical analysis in MATLAB.
Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
- Kumar, Shantanu, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: IEEE PES Asia-Pacific Power and Energy Engineering Conference, APPEEC 2015; Brisbane, Australia; 15th-18th November 2015 Vol. 2016, p. 1-5
- Full Text:
- Reviewed:
- Description: Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED's) to carry out multiple functions in process bus devices. This paper presents simulation results with respect to the delay in packets transfer in an Ethernet environment. Understanding the delay in packet transfer of Generic Object Oriented Substation Event (GOOSE) and Sampled Values (SV) shall assist the user in understanding the substation automation, control and protection of substation primary plants such as current transformers (CT's), voltage transformers (VT's), circuit breakers etc. connected in the network during a fault condition Conventional substation uses Merging Units (MU's) to communicate with the IED's featuring IEC 61850-9-2 standard. This standard exhibits transparency and standardization of data communication while addressing issues related to reliability, packet sharing, and maintainability, etc. However, process bus architecture is yet to be widely accepted in the industry and needs further validation due to lack of confidence. This paper evaluates the performance of a digital protection scheme in a zone substation operating at 132kV, featuring IEC 61850-9-2 IED's and using an optimized network engineering tool (OPNET) simulator. Understanding the delay in receiving time critical GOOSE and sampled value SV messages from protection perspective is critical as loss of data could cause malfunction in the protection jeopardizing vital substation plants.
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: IEEE PES Asia-Pacific Power and Energy Engineering Conference, APPEEC 2015; Brisbane, Australia; 15th-18th November 2015 Vol. 2016, p. 1-5
- Full Text:
- Reviewed:
- Description: Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED's) to carry out multiple functions in process bus devices. This paper presents simulation results with respect to the delay in packets transfer in an Ethernet environment. Understanding the delay in packet transfer of Generic Object Oriented Substation Event (GOOSE) and Sampled Values (SV) shall assist the user in understanding the substation automation, control and protection of substation primary plants such as current transformers (CT's), voltage transformers (VT's), circuit breakers etc. connected in the network during a fault condition Conventional substation uses Merging Units (MU's) to communicate with the IED's featuring IEC 61850-9-2 standard. This standard exhibits transparency and standardization of data communication while addressing issues related to reliability, packet sharing, and maintainability, etc. However, process bus architecture is yet to be widely accepted in the industry and needs further validation due to lack of confidence. This paper evaluates the performance of a digital protection scheme in a zone substation operating at 132kV, featuring IEC 61850-9-2 IED's and using an optimized network engineering tool (OPNET) simulator. Understanding the delay in receiving time critical GOOSE and sampled value SV messages from protection perspective is critical as loss of data could cause malfunction in the protection jeopardizing vital substation plants.
Performance monitoring of a PMU in a microgrid environment based on IEC 61850-90-5
- Kumar, Shantanu, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: Reliable protection, communication and control are the key features of a digital protection scheme in a utility substation. Microgrid is an alternative solution of installing long Transmission & Distribution lines could be cost prohibitive. There are number of Intelligent Electronic Devices (IEDs) which could find applications in controlling and monitoring of power network in a Microgrid set up and one such device is Phasor Measurement Unit (PMU). It is a microprocessor based intelligent device which gathers high-resolution data, checks the power quality and records disturbances. However, few issues that remains to be addressed such as, interoperability in a multi-vendor equipment and coordination between individual control systems in an integrated scheme. In this paper, an Operational Network Technology (OPNET) software model of a PMU has been designed and tested for its performance in a Microgrid environment based on IEC 61850-90-5 standard.
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: Reliable protection, communication and control are the key features of a digital protection scheme in a utility substation. Microgrid is an alternative solution of installing long Transmission & Distribution lines could be cost prohibitive. There are number of Intelligent Electronic Devices (IEDs) which could find applications in controlling and monitoring of power network in a Microgrid set up and one such device is Phasor Measurement Unit (PMU). It is a microprocessor based intelligent device which gathers high-resolution data, checks the power quality and records disturbances. However, few issues that remains to be addressed such as, interoperability in a multi-vendor equipment and coordination between individual control systems in an integrated scheme. In this paper, an Operational Network Technology (OPNET) software model of a PMU has been designed and tested for its performance in a Microgrid environment based on IEC 61850-90-5 standard.
Software implementation of two seamless redundant topologies in a digital protection system based on IEC 62439-3
- Kumar, Shantanu, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: Substations are the junctions of any transmission and distribution network in utilities. They carry bulk power to the customers using transmission network involving high voltage (HV) apparatus. Protection of HV equipment during a fault is the primary concern of an operator. Advancement in design and manufacturing of Intelligent Electronic Devices (IEDs) and IEC 61850 are finding increased application in utilities from automation and communication perspective, which addresses few shortcomings that couldn't be resolved in a conventional system. However there are few challenges in the digital scheme such as end to end delays in the packet transfer and interoperability of devices. Utilities are able to perceive these benefits by leveraging on IEC 62439-3 which has two important topologies i.e. Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR). It offers seamless redundancy in digital protection network without compromising the availability and downtime cost. In this paper, an Optimized Network Engineering Tool (OPNET) is used to simulate and compare the performance of these topologies with respect to delay time.
- Description: Proceedings of the 2016 Australasian Universities Power Engineering Conference, AUPEC 2016
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: Substations are the junctions of any transmission and distribution network in utilities. They carry bulk power to the customers using transmission network involving high voltage (HV) apparatus. Protection of HV equipment during a fault is the primary concern of an operator. Advancement in design and manufacturing of Intelligent Electronic Devices (IEDs) and IEC 61850 are finding increased application in utilities from automation and communication perspective, which addresses few shortcomings that couldn't be resolved in a conventional system. However there are few challenges in the digital scheme such as end to end delays in the packet transfer and interoperability of devices. Utilities are able to perceive these benefits by leveraging on IEC 62439-3 which has two important topologies i.e. Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR). It offers seamless redundancy in digital protection network without compromising the availability and downtime cost. In this paper, an Optimized Network Engineering Tool (OPNET) is used to simulate and compare the performance of these topologies with respect to delay time.
- Description: Proceedings of the 2016 Australasian Universities Power Engineering Conference, AUPEC 2016
Stochastic modeling of the output power of photovoltaic generators in various weather conditions
- Batool, Munira, Islam, Syed, Shahnia, Farhad
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: The intermittency of solar-powered energy sources prompt the uncertainty of load management. The influence of shading (whatever the reason may be) directly diminishes the feasible output power of the photovoltaic (PV) generators. The major causes of shading are the weather condition changes like the clouds, storms, and rains. Thereby, the dispatchable power for a distinct weather condition at an explicit time frame needs to be quantified. The stochastic modeling of a practical PV system has been performed in this paper. A step-by-step MATLAB-based algorithm is developed for tracking of dispatchable power limit using the Monte Carlo Principle. The proposed algorithm describes the weather condition as a function of cloud presence. The prescribed characteristics consist of the solar irradiance and the ambient temperature. The impact of weather changes on the output power of a PV system is evaluated by this algorithm. The results of this research are concluded by realistic data analysis taken from the Australian bureau of meteorology.
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: The intermittency of solar-powered energy sources prompt the uncertainty of load management. The influence of shading (whatever the reason may be) directly diminishes the feasible output power of the photovoltaic (PV) generators. The major causes of shading are the weather condition changes like the clouds, storms, and rains. Thereby, the dispatchable power for a distinct weather condition at an explicit time frame needs to be quantified. The stochastic modeling of a practical PV system has been performed in this paper. A step-by-step MATLAB-based algorithm is developed for tracking of dispatchable power limit using the Monte Carlo Principle. The proposed algorithm describes the weather condition as a function of cloud presence. The prescribed characteristics consist of the solar irradiance and the ambient temperature. The impact of weather changes on the output power of a PV system is evaluated by this algorithm. The results of this research are concluded by realistic data analysis taken from the Australian bureau of meteorology.
Analysis of end-to-end delay characteristics for various packets in IEC 61850 substation communications system
- Das, Narottam, Ma, Wu, Islam, Syed
- Authors: Das, Narottam , Ma, Wu , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: 25th Australasian Universities Power Engineering Conference, AUPEC 2015, Wollongong, Australia; 27th-30th September 2015 p. 1-5
- Full Text:
- Reviewed:
- Description: Substation plays an important role in power system communications for safe and reliable operation of entire power networks. Substation communication networks are connected with various substation intelligent electronic devices (IEDs), which is substation systems lifeblood and the system availability is decided by its real-Time performance. International Electro-Technical Commission (IEC) has been developed the standards based on object-oriented technologies for substation automation. IEC 61850 protocol has been applied widely in substation communication applications. It presents new challenges to realtime performance simulation and testing of protective relays. In this paper, an optimized network engineering tool (OPNET) or Riverbed modeler simulation tool/ software has been used for the modeling of IED in substation level network. Based on the simulation results, different types of data stream have been discussed, such as, periodic data stream, random data stream and burst data steam. The typical studies using these models, to construct substation automation system (SAS) network on the OPNET modeler or Riverbed modeler was made to reveal the impact of each affecting parameter or factor to the real-Time performance of substation communications system, which is also incorporated in this report.
- Description: 2015 Australasian Universities Power Engineering Conference: Challenges for Future Grids, AUPEC 2015
- Authors: Das, Narottam , Ma, Wu , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: 25th Australasian Universities Power Engineering Conference, AUPEC 2015, Wollongong, Australia; 27th-30th September 2015 p. 1-5
- Full Text:
- Reviewed:
- Description: Substation plays an important role in power system communications for safe and reliable operation of entire power networks. Substation communication networks are connected with various substation intelligent electronic devices (IEDs), which is substation systems lifeblood and the system availability is decided by its real-Time performance. International Electro-Technical Commission (IEC) has been developed the standards based on object-oriented technologies for substation automation. IEC 61850 protocol has been applied widely in substation communication applications. It presents new challenges to realtime performance simulation and testing of protective relays. In this paper, an optimized network engineering tool (OPNET) or Riverbed modeler simulation tool/ software has been used for the modeling of IED in substation level network. Based on the simulation results, different types of data stream have been discussed, such as, periodic data stream, random data stream and burst data steam. The typical studies using these models, to construct substation automation system (SAS) network on the OPNET modeler or Riverbed modeler was made to reveal the impact of each affecting parameter or factor to the real-Time performance of substation communications system, which is also incorporated in this report.
- Description: 2015 Australasian Universities Power Engineering Conference: Challenges for Future Grids, AUPEC 2015
Disconnection time and sequence of rooftop PVs under short-circuit faults in low voltage networks
- Yengejeh, Hadi, Shahnia, Farhad, Islam, Syed
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: North American Power Symposium, NAPS 2015; Charlotte, United States; 4th-6th October 2015 p. 1-6
- Full Text:
- Reviewed:
- Description: This paper presents an analysis on the disconnection time of single-phase rooftop PVs, located in a three-phase four-wire low voltage distribution feeder after a line-to-ground short-circuit fault on the low voltage feeder. The paper aims to evaluate and discuss the disconnection time and sequence of PVs in a network with 100% PV penetration level. The impact of different parameters such as the location of the fault, impedance of the fault and the ratio of PVs generation capacity to the load demand are considered. Furthermore, the effect of the system earthing in the form of multiple earthed neutral and non-effectively grounded systems are evaluated on the PVs disconnection time. The analyses intend to figure out the conditions under which the PVs in the feeder may fail to disconnect after a line-to-ground fault and keep feeding the fault. The analyses are carried out in PSCAD/EMTDC software.
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: North American Power Symposium, NAPS 2015; Charlotte, United States; 4th-6th October 2015 p. 1-6
- Full Text:
- Reviewed:
- Description: This paper presents an analysis on the disconnection time of single-phase rooftop PVs, located in a three-phase four-wire low voltage distribution feeder after a line-to-ground short-circuit fault on the low voltage feeder. The paper aims to evaluate and discuss the disconnection time and sequence of PVs in a network with 100% PV penetration level. The impact of different parameters such as the location of the fault, impedance of the fault and the ratio of PVs generation capacity to the load demand are considered. Furthermore, the effect of the system earthing in the form of multiple earthed neutral and non-effectively grounded systems are evaluated on the PVs disconnection time. The analyses intend to figure out the conditions under which the PVs in the feeder may fail to disconnect after a line-to-ground fault and keep feeding the fault. The analyses are carried out in PSCAD/EMTDC software.
High performance communication redundancy in a digital substation based on IEC 62439-3 with a station bus configuration
- Kumar, Shantanu, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: 25th Australasian Universities Power Engineering Conference, AUPEC 2015; Wollongong, Australia; 27th-30th September 2015 p. 1-5
- Full Text:
- Reviewed:
- Description: High speed communication is critical in a digital substation from protection, control and automation perspectives. Although International Electro-Technical Commission (IEC) 61850 standard has proven to be a reliable guide for the substation automation and communication systems, yet it has few shortcomings in offering redundancies in the protection architecture, which has been addressed better in IEC 62439-3 standard encompassing Parallel Redundancy Protocol (PRP) and High-Availability Seamless Redundancy (HSR). Due to single port failure, data losses and interoperability issues related to multi-vendor equipment, IEC working committee had to look beyond IEC 61850 standard. The enhanced features in a Doubly Attached Node components based on IEC 62439-3 provides redundancy in protection having two active frames circulating data packets in the ring. These frames send out copies in the ring and should one of the frame is lost, the other copy manages to reach the destination node via an alternate path, ensuring flawless data transfer at a significant faster speed using multi-vendor equipment and fault resilient circuits. The PRP and HSR topologies provides higher performance in a digitally protected substation and promise better future over the IEC 61850 standard due to its faster processing capabilities, increased availability and minimum delay in data packet transfer and wireless communication in the network. This paper exhibits the performance of PRP and HSR topologies focusing on the redundancy achievement within the network and at the end nodes of a station bus ring architecture, based on IEC 62439-3.
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2015
- Type: Text , Conference proceedings , Conference paper
- Relation: 25th Australasian Universities Power Engineering Conference, AUPEC 2015; Wollongong, Australia; 27th-30th September 2015 p. 1-5
- Full Text:
- Reviewed:
- Description: High speed communication is critical in a digital substation from protection, control and automation perspectives. Although International Electro-Technical Commission (IEC) 61850 standard has proven to be a reliable guide for the substation automation and communication systems, yet it has few shortcomings in offering redundancies in the protection architecture, which has been addressed better in IEC 62439-3 standard encompassing Parallel Redundancy Protocol (PRP) and High-Availability Seamless Redundancy (HSR). Due to single port failure, data losses and interoperability issues related to multi-vendor equipment, IEC working committee had to look beyond IEC 61850 standard. The enhanced features in a Doubly Attached Node components based on IEC 62439-3 provides redundancy in protection having two active frames circulating data packets in the ring. These frames send out copies in the ring and should one of the frame is lost, the other copy manages to reach the destination node via an alternate path, ensuring flawless data transfer at a significant faster speed using multi-vendor equipment and fault resilient circuits. The PRP and HSR topologies provides higher performance in a digitally protected substation and promise better future over the IEC 61850 standard due to its faster processing capabilities, increased availability and minimum delay in data packet transfer and wireless communication in the network. This paper exhibits the performance of PRP and HSR topologies focusing on the redundancy achievement within the network and at the end nodes of a station bus ring architecture, based on IEC 62439-3.
Contributions of single–phase rooftop PVs on short circuits faults in residential feeders
- Yengejeh, Hadi, Shahnia, Farhad, Islam, Syed
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 24th Australasian Universities Power Engineering Conference, AUPEC 2014; Perth, Australia; 28th September-1st October 2014 p. 1-6
- Full Text:
- Reviewed:
- Description: Sensitivity analysis results are presented to investigate the presence of single–phase rooftop Photovoltaic Cells (PV) in low voltage residential feeders, during short circuits in the overhead lines. The PV rating and location in the feeder and the fault location are considered as the variables of the sensitivity analysis. The single–phase faults are the main focus of this paper and the PV effect on fault current, current in distribution transformer secondary and the voltage at each bus of the feeder are investigated, during fault. Furthermore, to analyze the bus voltages and fault current in the presence of multiple PVs, each with different rating and location, a stochastic analysis is carried out to investigate the expected probability density function of these parameters, considering the uncertainties of PV rating and location as well as fault location.
- Authors: Yengejeh, Hadi , Shahnia, Farhad , Islam, Syed
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 24th Australasian Universities Power Engineering Conference, AUPEC 2014; Perth, Australia; 28th September-1st October 2014 p. 1-6
- Full Text:
- Reviewed:
- Description: Sensitivity analysis results are presented to investigate the presence of single–phase rooftop Photovoltaic Cells (PV) in low voltage residential feeders, during short circuits in the overhead lines. The PV rating and location in the feeder and the fault location are considered as the variables of the sensitivity analysis. The single–phase faults are the main focus of this paper and the PV effect on fault current, current in distribution transformer secondary and the voltage at each bus of the feeder are investigated, during fault. Furthermore, to analyze the bus voltages and fault current in the presence of multiple PVs, each with different rating and location, a stochastic analysis is carried out to investigate the expected probability density function of these parameters, considering the uncertainties of PV rating and location as well as fault location.
A review on chemical diagnosis techniques for transformer paper insulation degradation
- Abu Bakar, Norazhar, Abu Siada, Ahmed, Islam, Syed
- Authors: Abu Bakar, Norazhar , Abu Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 Australasian Universities Power Engineering Conference, AUPEC 2013; Hobart, Australia; 29th September-3rd October 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: Energized parts within power transformer are isolated using paper insulation and are immersed in insulating oil. Hence, transformer oil and paper insulation are essential sources to detect incipient and fast developing power transformer faults. Several chemical diagnoses techniques are developed to examine the condition of paper insulation such as degree of polymerization, carbon oxides, furanic compounds and methanol. The principle and limitation of these diagnoses are discussed and compared in this paper.
- Authors: Abu Bakar, Norazhar , Abu Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 Australasian Universities Power Engineering Conference, AUPEC 2013; Hobart, Australia; 29th September-3rd October 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: Energized parts within power transformer are isolated using paper insulation and are immersed in insulating oil. Hence, transformer oil and paper insulation are essential sources to detect incipient and fast developing power transformer faults. Several chemical diagnoses techniques are developed to examine the condition of paper insulation such as degree of polymerization, carbon oxides, furanic compounds and methanol. The principle and limitation of these diagnoses are discussed and compared in this paper.
Estimation of induction motor parameters using hybrid algorithms for power system dynamic studies
- Susanto, Julius, Islam, Syed
- Authors: Susanto, Julius , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 Australasian Universities Power Engineering Conference, AUPEC 2013; Hobart, Australia; 29th September-3rd October 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: This paper proposes a hybrid Newton-Raphson and genetic algorithm for the estimation of double cage induction motor parameters from commonly available manufacturer data. The hybrid algorithm was tested on a large data set of 6,380 IEC and NEMA motors and then compared with a baseline Newton-Raphson algorithm. The simulation results show that while the proposed hybrid algorithm is more computationally intensive, it does make significant improvements to convergence and error rates.
- Authors: Susanto, Julius , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 Australasian Universities Power Engineering Conference, AUPEC 2013; Hobart, Australia; 29th September-3rd October 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: This paper proposes a hybrid Newton-Raphson and genetic algorithm for the estimation of double cage induction motor parameters from commonly available manufacturer data. The hybrid algorithm was tested on a large data set of 6,380 IEC and NEMA motors and then compared with a baseline Newton-Raphson algorithm. The simulation results show that while the proposed hybrid algorithm is more computationally intensive, it does make significant improvements to convergence and error rates.
Image processing-based on-line technique to detect power transformer winding faults
- Abu-Siada, Ahmed, Islam, Syed
- Authors: Abu-Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 39th Annual Conference of the IEEE Industrial Electronics Society, IECON 2013; Vienna, Austria; 10th-14th November 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: Frequency Response Analysis (FRA) has been growing in popularity in recent times as a tool to detect mechanical deformation within power transformers. To conduct the test, the transformer has to be taken out of service which may cause interruption to the electricity grid. Moreover, because FRA relies on graphical analysis, it calls for an expert person to analyse the results as so far, there is no standard code for FRA interpretation worldwide. In this paper an online technique is introduced to detect the internal faults within a power transformer by constructing the voltage-current (V-I) locus diagram to provide a current state of the transformer health condition. The technique does not call for any special equipment as it uses the existing metering devices attached to any power transformer to monitor the input voltage, output voltage and the input current at the power frequency and hence online monitoring can be realised. Various types of faults have been simulated to assess its impact on the proposed locus. A Matlab code based on digital image processing is developed to calculate any deviation of the V-I locus with respect to the reference one and to identify the type of fault.
- Authors: Abu-Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 39th Annual Conference of the IEEE Industrial Electronics Society, IECON 2013; Vienna, Austria; 10th-14th November 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: Frequency Response Analysis (FRA) has been growing in popularity in recent times as a tool to detect mechanical deformation within power transformers. To conduct the test, the transformer has to be taken out of service which may cause interruption to the electricity grid. Moreover, because FRA relies on graphical analysis, it calls for an expert person to analyse the results as so far, there is no standard code for FRA interpretation worldwide. In this paper an online technique is introduced to detect the internal faults within a power transformer by constructing the voltage-current (V-I) locus diagram to provide a current state of the transformer health condition. The technique does not call for any special equipment as it uses the existing metering devices attached to any power transformer to monitor the input voltage, output voltage and the input current at the power frequency and hence online monitoring can be realised. Various types of faults have been simulated to assess its impact on the proposed locus. A Matlab code based on digital image processing is developed to calculate any deviation of the V-I locus with respect to the reference one and to identify the type of fault.
Impact of axial displacement on power transformer FRA signature
- Hashemnia, Naser, Abu-Siada, Ahmed, Islam, Syed
- Authors: Hashemnia, Naser , Abu-Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 IEEE Power and Energy Society General Meeting, PES 2013; Vancouver, Canada; 21st-25th July 2013 p. 1-4
- Full Text:
- Reviewed:
- Description: Frequency response analysis (FRA) is gaining global popularity in detecting power transformer winding movement due to the development of FRA test equipment. However, because FRA relies on graphical analysis, interpretation of its signatures is still a very specialized area that calls for skillful personnel to detect the sort and likely place of the fault as so far, there is no reliable standard code for FRA signature classification and quantification. This paper investigates the impact of transformer winding axial displacement on its FRA signature as a step toward the establishment of reliable codes for FRA interpretation. In this context a detailed model for a singlephase transformer is simulated using 3D finite element analysis to emulate a close to real transformer. The impact of axial displacement on the electrical distributed parameters model that are calculated based on the transformer physical dimension is examined to investigate how model’s parameters including inductance and capacitance matrices change when axial displacement takes place within a power transformer.
- Authors: Hashemnia, Naser , Abu-Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 IEEE Power and Energy Society General Meeting, PES 2013; Vancouver, Canada; 21st-25th July 2013 p. 1-4
- Full Text:
- Reviewed:
- Description: Frequency response analysis (FRA) is gaining global popularity in detecting power transformer winding movement due to the development of FRA test equipment. However, because FRA relies on graphical analysis, interpretation of its signatures is still a very specialized area that calls for skillful personnel to detect the sort and likely place of the fault as so far, there is no reliable standard code for FRA signature classification and quantification. This paper investigates the impact of transformer winding axial displacement on its FRA signature as a step toward the establishment of reliable codes for FRA interpretation. In this context a detailed model for a singlephase transformer is simulated using 3D finite element analysis to emulate a close to real transformer. The impact of axial displacement on the electrical distributed parameters model that are calculated based on the transformer physical dimension is examined to investigate how model’s parameters including inductance and capacitance matrices change when axial displacement takes place within a power transformer.
- «
- ‹
- 1
- ›
- »