A fault-tolerant cascaded switched-capacitor multilevel inverter for domestic applications in smart grids
- Akbari, Ehsan, Teimouri, Ali, Saki, Mojtaba, Rezaei, Mohammad, Hu, Jiefeng, Band, Shahab, Pai, Hao-Ting, Mosavi, Amir
- Authors: Akbari, Ehsan , Teimouri, Ali , Saki, Mojtaba , Rezaei, Mohammad , Hu, Jiefeng , Band, Shahab , Pai, Hao-Ting , Mosavi, Amir
- Date: 2022
- Type: Text , Journal article
- Relation: IEEE Access Vol. 10, no. (2022), p. 110590-110602
- Full Text:
- Reviewed:
- Description: Cascaded multilevel inverters (MLIs) generate an output voltage using series-connected power modules that employ standard configurations of low-voltage components. Each module may employ one or more switched capacitors to double or quadruple its input voltage. The higher number of switched capacitors and semiconductor switches in MLIs compared to conventional two-level inverters has led to concerns about overall system reliability. A fault-tolerant design can mitigate this reliability issue. If one part of the system fails, the MLI can continue its planned operation at a reduced level rather than the entire system failing, which makes the fault tolerance of the MLI particularly important. In this paper, a novel fault location technique is presented that leads to a significant reduction in fault location detection time based on the reliability priority of the components of the proposed fault-tolerant switched capacitor cascaded MLI (CSCMLI). The main contribution of this paper is to reduce the number of MLI switches under fault conditions while operating at lower levels. The fault-tolerant inverter requires fewer switches at higher reliability, and the comparison with similar MLIs shows a faster dynamic response of fault detection and reduced fault location detection time. The experimental results confirm the effectiveness of the presented methods applied in the CSCMLI. Also, all experimental data including processor code, schematic, PCB, and video of CSCMLI operation are attached. © 2013 IEEE.
- Authors: Akbari, Ehsan , Teimouri, Ali , Saki, Mojtaba , Rezaei, Mohammad , Hu, Jiefeng , Band, Shahab , Pai, Hao-Ting , Mosavi, Amir
- Date: 2022
- Type: Text , Journal article
- Relation: IEEE Access Vol. 10, no. (2022), p. 110590-110602
- Full Text:
- Reviewed:
- Description: Cascaded multilevel inverters (MLIs) generate an output voltage using series-connected power modules that employ standard configurations of low-voltage components. Each module may employ one or more switched capacitors to double or quadruple its input voltage. The higher number of switched capacitors and semiconductor switches in MLIs compared to conventional two-level inverters has led to concerns about overall system reliability. A fault-tolerant design can mitigate this reliability issue. If one part of the system fails, the MLI can continue its planned operation at a reduced level rather than the entire system failing, which makes the fault tolerance of the MLI particularly important. In this paper, a novel fault location technique is presented that leads to a significant reduction in fault location detection time based on the reliability priority of the components of the proposed fault-tolerant switched capacitor cascaded MLI (CSCMLI). The main contribution of this paper is to reduce the number of MLI switches under fault conditions while operating at lower levels. The fault-tolerant inverter requires fewer switches at higher reliability, and the comparison with similar MLIs shows a faster dynamic response of fault detection and reduced fault location detection time. The experimental results confirm the effectiveness of the presented methods applied in the CSCMLI. Also, all experimental data including processor code, schematic, PCB, and video of CSCMLI operation are attached. © 2013 IEEE.
False data detection in a clustered smart grid using unscented Kalman filter
- Rashed, Muhammad, Kamruzzaman, Joarder, Gondal, Iqbal, Islam, Syed
- Authors: Rashed, Muhammad , Kamruzzaman, Joarder , Gondal, Iqbal , Islam, Syed
- Date: 2022
- Type: Text , Journal article
- Relation: IEEE Access Vol. 10, no. (2022), p. 78548-78556
- Full Text:
- Reviewed:
- Description: The smart grid accessibility over the Internet of Things (IoT) is becoming attractive to electrical grid operators as it brings considerable operational and cost efficiencies. However, this in return creates significant cyber security challenges, such as fortification of state estimation data such as state variables against false data injection attacks (FDIAs). In this paper, a clustered partitioning state estimation (CPSE) technique is proposed to detect FDIA by using static state estimation, namely, weighted least square (WLS) method in conjunction with dynamic state estimation using minimum variance unscented Kalman filter (MV-UKF) which improves the accuracy of state estimation. The estimates acquired from the MV-UKF do not deviate like WLS as these are purely based on the previous iteration saved in the transition matrix. The deviation between the corresponding estimations of WLS and MV-UKF are utilised to partition the smart grid into smaller sub-systems to detect FDIA and then identify its location. To validate the proposed detection technique, FIDAs are injected into IEEE 14-bus, IEEE 30-bus, IEEE 118-bus, and IEEE 300-bus distribution feeder using MATPOWER simulation platform. Our results clearly demonstrate that the proposed technique can locate the attack area efficiently compared to other techniques such as chi square. © 2013 IEEE.
- Authors: Rashed, Muhammad , Kamruzzaman, Joarder , Gondal, Iqbal , Islam, Syed
- Date: 2022
- Type: Text , Journal article
- Relation: IEEE Access Vol. 10, no. (2022), p. 78548-78556
- Full Text:
- Reviewed:
- Description: The smart grid accessibility over the Internet of Things (IoT) is becoming attractive to electrical grid operators as it brings considerable operational and cost efficiencies. However, this in return creates significant cyber security challenges, such as fortification of state estimation data such as state variables against false data injection attacks (FDIAs). In this paper, a clustered partitioning state estimation (CPSE) technique is proposed to detect FDIA by using static state estimation, namely, weighted least square (WLS) method in conjunction with dynamic state estimation using minimum variance unscented Kalman filter (MV-UKF) which improves the accuracy of state estimation. The estimates acquired from the MV-UKF do not deviate like WLS as these are purely based on the previous iteration saved in the transition matrix. The deviation between the corresponding estimations of WLS and MV-UKF are utilised to partition the smart grid into smaller sub-systems to detect FDIA and then identify its location. To validate the proposed detection technique, FIDAs are injected into IEEE 14-bus, IEEE 30-bus, IEEE 118-bus, and IEEE 300-bus distribution feeder using MATPOWER simulation platform. Our results clearly demonstrate that the proposed technique can locate the attack area efficiently compared to other techniques such as chi square. © 2013 IEEE.
Energy efficiency perspectives of femtocells in internet of things : recent advances and challenges
- Al-Turjman, Fadi, Imran, Muhammad, Bakhsh, Sheikh
- Authors: Al-Turjman, Fadi , Imran, Muhammad , Bakhsh, Sheikh
- Date: 2017
- Type: Text , Journal article
- Relation: IEEE Access Vol. 5, no. (2017), p. 26808-26818
- Full Text:
- Reviewed:
- Description: Energy efficiency is a growing concern in every aspect of the technology. Apart from maintaining profitability, energy efficiency means a decrease in the overall environmental effects, which is a serious concern in today's world. Using a femtocell in Internet of Things (IoT) can boost energy efficiency. To illustrate, femtocells can be used in smart homes, which is a subpart of the smart grid, as a communication mechanism in order to manage energy efficiency. Moreover, femtocells can be used in many IoT applications in order to provide communication. However, it is important to evaluate the energy efficiency of femtocells. This paper investigates recent advances and challenges in the energy efficiency of the femtocell in IoT. First, we introduce the idea of femtocells in the context of IoT and their role in IoT applications. Next, we describe prominent performance metrics in order to understand how the energy efficiency is evaluated. Then, we elucidate how energy can be modeled in terms of femtocell and provide some models from the literature. Since femtocells are used in heterogeneous networks to manage energy efficiency, we also express some energy efficiency schemes for deployment. The factors that affect the energy usage of a femtocell base station are discussed and then the power consumption of user equipment under femtocell coverage is mentioned. Finally, we highlight prominent open research issues and challenges. © 2013 IEEE.
- Authors: Al-Turjman, Fadi , Imran, Muhammad , Bakhsh, Sheikh
- Date: 2017
- Type: Text , Journal article
- Relation: IEEE Access Vol. 5, no. (2017), p. 26808-26818
- Full Text:
- Reviewed:
- Description: Energy efficiency is a growing concern in every aspect of the technology. Apart from maintaining profitability, energy efficiency means a decrease in the overall environmental effects, which is a serious concern in today's world. Using a femtocell in Internet of Things (IoT) can boost energy efficiency. To illustrate, femtocells can be used in smart homes, which is a subpart of the smart grid, as a communication mechanism in order to manage energy efficiency. Moreover, femtocells can be used in many IoT applications in order to provide communication. However, it is important to evaluate the energy efficiency of femtocells. This paper investigates recent advances and challenges in the energy efficiency of the femtocell in IoT. First, we introduce the idea of femtocells in the context of IoT and their role in IoT applications. Next, we describe prominent performance metrics in order to understand how the energy efficiency is evaluated. Then, we elucidate how energy can be modeled in terms of femtocell and provide some models from the literature. Since femtocells are used in heterogeneous networks to manage energy efficiency, we also express some energy efficiency schemes for deployment. The factors that affect the energy usage of a femtocell base station are discussed and then the power consumption of user equipment under femtocell coverage is mentioned. Finally, we highlight prominent open research issues and challenges. © 2013 IEEE.
- «
- ‹