Performance evaluation of a process bus architecture in a zone substation based on IEC 61850-9-2
- Kumar, Shantanu, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: IEEE PES Asia-Pacific Power and Energy Engineering Conference, APPEEC 2015; Brisbane, Australia; 15th-18th November 2015 Vol. 2016, p. 1-5
- Full Text:
- Reviewed:
- Description: Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED's) to carry out multiple functions in process bus devices. This paper presents simulation results with respect to the delay in packets transfer in an Ethernet environment. Understanding the delay in packet transfer of Generic Object Oriented Substation Event (GOOSE) and Sampled Values (SV) shall assist the user in understanding the substation automation, control and protection of substation primary plants such as current transformers (CT's), voltage transformers (VT's), circuit breakers etc. connected in the network during a fault condition Conventional substation uses Merging Units (MU's) to communicate with the IED's featuring IEC 61850-9-2 standard. This standard exhibits transparency and standardization of data communication while addressing issues related to reliability, packet sharing, and maintainability, etc. However, process bus architecture is yet to be widely accepted in the industry and needs further validation due to lack of confidence. This paper evaluates the performance of a digital protection scheme in a zone substation operating at 132kV, featuring IEC 61850-9-2 IED's and using an optimized network engineering tool (OPNET) simulator. Understanding the delay in receiving time critical GOOSE and sampled value SV messages from protection perspective is critical as loss of data could cause malfunction in the protection jeopardizing vital substation plants.
- Authors: Kumar, Shantanu , Das, Narottam , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: IEEE PES Asia-Pacific Power and Energy Engineering Conference, APPEEC 2015; Brisbane, Australia; 15th-18th November 2015 Vol. 2016, p. 1-5
- Full Text:
- Reviewed:
- Description: Ethernet communication has been the back bone of high speed communication in digital substations from protection relaying, control and automation perspective. Major substation manufacturers have been constantly upgrading softwares and adding new features in their Intelligent Electronic Devices (IED's) to carry out multiple functions in process bus devices. This paper presents simulation results with respect to the delay in packets transfer in an Ethernet environment. Understanding the delay in packet transfer of Generic Object Oriented Substation Event (GOOSE) and Sampled Values (SV) shall assist the user in understanding the substation automation, control and protection of substation primary plants such as current transformers (CT's), voltage transformers (VT's), circuit breakers etc. connected in the network during a fault condition Conventional substation uses Merging Units (MU's) to communicate with the IED's featuring IEC 61850-9-2 standard. This standard exhibits transparency and standardization of data communication while addressing issues related to reliability, packet sharing, and maintainability, etc. However, process bus architecture is yet to be widely accepted in the industry and needs further validation due to lack of confidence. This paper evaluates the performance of a digital protection scheme in a zone substation operating at 132kV, featuring IEC 61850-9-2 IED's and using an optimized network engineering tool (OPNET) simulator. Understanding the delay in receiving time critical GOOSE and sampled value SV messages from protection perspective is critical as loss of data could cause malfunction in the protection jeopardizing vital substation plants.
Two-stage approach for the assessment of distributed generation capacity mixture in active distribution networks
- Jayaweera, Dilan, Islam, Syed, Neduvelil, Sandeep
- Authors: Jayaweera, Dilan , Islam, Syed , Neduvelil, Sandeep
- Date: 2013
- Type: Text , Journal article
- Relation: Journal of Renewable and Sustainable Energy Vol. 5, no. 5 (2013), p.
- Full Text:
- Reviewed:
- Description: Distribution networks are limited with spare capacities to integrate increased volumes of distributed generation (DG). Network constraints and congestion, dynamic thermal limits, intermittent outputs, and the need for reduction in greenhouse gas emission increase the complexity of capturing optimal DG mixture that can safely permit the optimal operation. This paper investigates this problem in detail and proposes a two-stage approach for the quantification of optimal DG capacity mixture in an active distribution network. The approach is aimed at operational planning and takes into account dynamic thermal limits, network internal benefit, and network external benefit and then optimizes samples of DG mixtures through sequential simulation. A case study is performed incorporating wind and photovoltaic generation as intermittent DG and diesel units as standing reserve units. Results suggest that specific operating conditions in an active distribution network can dominate the optimal DG mixture. Wind and diesel hybrid operation can be the most beneficial DG mixture compared to any other DG combination. Dynamic thermal limits of assets can potentially control the type of DG of the optimized mixture.
- Authors: Jayaweera, Dilan , Islam, Syed , Neduvelil, Sandeep
- Date: 2013
- Type: Text , Journal article
- Relation: Journal of Renewable and Sustainable Energy Vol. 5, no. 5 (2013), p.
- Full Text:
- Reviewed:
- Description: Distribution networks are limited with spare capacities to integrate increased volumes of distributed generation (DG). Network constraints and congestion, dynamic thermal limits, intermittent outputs, and the need for reduction in greenhouse gas emission increase the complexity of capturing optimal DG mixture that can safely permit the optimal operation. This paper investigates this problem in detail and proposes a two-stage approach for the quantification of optimal DG capacity mixture in an active distribution network. The approach is aimed at operational planning and takes into account dynamic thermal limits, network internal benefit, and network external benefit and then optimizes samples of DG mixtures through sequential simulation. A case study is performed incorporating wind and photovoltaic generation as intermittent DG and diesel units as standing reserve units. Results suggest that specific operating conditions in an active distribution network can dominate the optimal DG mixture. Wind and diesel hybrid operation can be the most beneficial DG mixture compared to any other DG combination. Dynamic thermal limits of assets can potentially control the type of DG of the optimized mixture.
Optimal placement of synchronized voltage traveling wave sensors in a radial distribution network
- Tashakkori, Ali, Abu-Siada, Ahmed, Wolfs, Peter, Islam, Syed
- Authors: Tashakkori, Ali , Abu-Siada, Ahmed , Wolfs, Peter , Islam, Syed
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Access Vol. 9, no. (2021), p. 65380-65387
- Full Text:
- Reviewed:
- Description: A transmission line fault generates transient high frequency travelling waves (TWs) that propagate through the entire network. The fault location can be determined by recording the instants at which the incident waves arrive at various points in the network. In single end-based methods, the incident wave arrival time and its subsequent reflections from the fault point are used to identify the fault location. In heavily branched distribution networks, the magnitude of the traveling wave declines rapidly as it passes through multiple junctions that cause reflection and refraction to the signal. Therefore, detecting the first incident wave from a high impedance fault is a significant challenge in the electrical distribution networks, in particular, subsequent reflections from a temporarily fault may not be possible. Therefore, to identify a high impedance or temporary faults in a distribution network with many branches, loads, switching devices and distributed transformers, multiple observers are required to observe the entire network. A fully observable and locatable network requires at least one observer per branch or spur which is not a cost effective solution. This paper proposes a reasonable number of relatively low-cost voltage TW observers with GPS time-synchronization and radio communication to detect and timestamp the TW arrival at several points in the network. In this regard, a method to optimally place a given number of TW detectors to maximize the network observability and locatability is presented. Results show the robustness of the proposed method to detect high impedance and intermittent faults within distribution networks with a minimum number of observers. © 2013 IEEE.
- Authors: Tashakkori, Ali , Abu-Siada, Ahmed , Wolfs, Peter , Islam, Syed
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Access Vol. 9, no. (2021), p. 65380-65387
- Full Text:
- Reviewed:
- Description: A transmission line fault generates transient high frequency travelling waves (TWs) that propagate through the entire network. The fault location can be determined by recording the instants at which the incident waves arrive at various points in the network. In single end-based methods, the incident wave arrival time and its subsequent reflections from the fault point are used to identify the fault location. In heavily branched distribution networks, the magnitude of the traveling wave declines rapidly as it passes through multiple junctions that cause reflection and refraction to the signal. Therefore, detecting the first incident wave from a high impedance fault is a significant challenge in the electrical distribution networks, in particular, subsequent reflections from a temporarily fault may not be possible. Therefore, to identify a high impedance or temporary faults in a distribution network with many branches, loads, switching devices and distributed transformers, multiple observers are required to observe the entire network. A fully observable and locatable network requires at least one observer per branch or spur which is not a cost effective solution. This paper proposes a reasonable number of relatively low-cost voltage TW observers with GPS time-synchronization and radio communication to detect and timestamp the TW arrival at several points in the network. In this regard, a method to optimally place a given number of TW detectors to maximize the network observability and locatability is presented. Results show the robustness of the proposed method to detect high impedance and intermittent faults within distribution networks with a minimum number of observers. © 2013 IEEE.
Assessing transformer oil quality using deep convolutional networks
- Alam, Mohammad, Karmakar, Gour, Islam, Syed, Kamruzzaman, Joarder, Chetty, Madhu, Lim, Suryani, Appuhamillage, Gayan, Chattopadhyay, Gopi, Wilcox, Steve, Verheyen, Vincent
- Authors: Alam, Mohammad , Karmakar, Gour , Islam, Syed , Kamruzzaman, Joarder , Chetty, Madhu , Lim, Suryani , Appuhamillage, Gayan , Chattopadhyay, Gopi , Wilcox, Steve , Verheyen, Vincent
- Date: 2019
- Type: Text , Conference proceedings , Conference paper
- Relation: 29th Australasian Universities Power Engineering Conference, AUPEC 2019
- Full Text:
- Reviewed:
- Description: Electrical power grids comprise a significantly large number of transformers that interconnect power generation, transmission and distribution. These transformers having different MVA ratings are critical assets that require proper maintenance to provide long and uninterrupted electrical service. The mineral oil, an essential component of any transformer, not only provides cooling but also acts as an insulating medium within the transformer. The quality and the key dissolved properties of insulating mineral oil for the transformer are critical with its proper and reliable operation. However, traditional chemical diagnostic methods are expensive and time-consuming. A transformer oil image analysis approach, based on the entropy value of oil, which is inexpensive, effective and quick. However, the inability of entropy to estimate the vital transformer oil properties such as equivalent age, Neutralization Number (NN), dissipation factor (tanδ) and power factor (PF); and many intuitively derived constants usage limit its estimation accuracy. To address this issue, in this paper, we introduce an innovative transformer oil analysis using two deep convolutional learning techniques such as Convolutional Neural Network (ConvNet) and Residual Neural Network (ResNet). These two deep neural networks are chosen for this project as they have superior performance in computer vision. After estimating the equivalent aging year of transformer oil from its image by our proposed method, NN, tanδ and PF are computed using that estimated age. Our deep learning based techniques can accurately predict the transformer oil equivalent age, leading to calculate NN, tanδ and PF more accurately. The root means square error of estimated equivalent age produced by entropy, ConvNet and ResNet based methods are 0.718, 0.122 and 0.065, respectively. ConvNet and ResNet based methods have reduced the error of the oil age estimation by 83% and 91%, respectively compared to that of the entropy method. Our proposed oil image analysis can calculate the equivalent age that is very close to the actual age for all images used in the experiment. © 2019 IEEE.
- Description: E1
- Authors: Alam, Mohammad , Karmakar, Gour , Islam, Syed , Kamruzzaman, Joarder , Chetty, Madhu , Lim, Suryani , Appuhamillage, Gayan , Chattopadhyay, Gopi , Wilcox, Steve , Verheyen, Vincent
- Date: 2019
- Type: Text , Conference proceedings , Conference paper
- Relation: 29th Australasian Universities Power Engineering Conference, AUPEC 2019
- Full Text:
- Reviewed:
- Description: Electrical power grids comprise a significantly large number of transformers that interconnect power generation, transmission and distribution. These transformers having different MVA ratings are critical assets that require proper maintenance to provide long and uninterrupted electrical service. The mineral oil, an essential component of any transformer, not only provides cooling but also acts as an insulating medium within the transformer. The quality and the key dissolved properties of insulating mineral oil for the transformer are critical with its proper and reliable operation. However, traditional chemical diagnostic methods are expensive and time-consuming. A transformer oil image analysis approach, based on the entropy value of oil, which is inexpensive, effective and quick. However, the inability of entropy to estimate the vital transformer oil properties such as equivalent age, Neutralization Number (NN), dissipation factor (tanδ) and power factor (PF); and many intuitively derived constants usage limit its estimation accuracy. To address this issue, in this paper, we introduce an innovative transformer oil analysis using two deep convolutional learning techniques such as Convolutional Neural Network (ConvNet) and Residual Neural Network (ResNet). These two deep neural networks are chosen for this project as they have superior performance in computer vision. After estimating the equivalent aging year of transformer oil from its image by our proposed method, NN, tanδ and PF are computed using that estimated age. Our deep learning based techniques can accurately predict the transformer oil equivalent age, leading to calculate NN, tanδ and PF more accurately. The root means square error of estimated equivalent age produced by entropy, ConvNet and ResNet based methods are 0.718, 0.122 and 0.065, respectively. ConvNet and ResNet based methods have reduced the error of the oil age estimation by 83% and 91%, respectively compared to that of the entropy method. Our proposed oil image analysis can calculate the equivalent age that is very close to the actual age for all images used in the experiment. © 2019 IEEE.
- Description: E1
Forced oscillation in power systems with converter controlled-based resources- a survey with case studies
- Surinkaew, Tossaporn, Emami, Koanoush, Shah, Rakibuzzaman, Islam, Syed, Mithulananthan, N.
- Authors: Surinkaew, Tossaporn , Emami, Koanoush , Shah, Rakibuzzaman , Islam, Syed , Mithulananthan, N.
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Access Vol. 9, no. (2021), p. 150911-150924
- Full Text:
- Reviewed:
- Description: In future power systems, conventional synchronous generators will be replaced by converter controlled-based generations (CCGs), i.e., wind and solar generations, and battery energy storage systems. Thus, the paradigm shift in power systems will lead to the inferior system strength and inertia scarcity. Therefore, the problems of forced oscillation (FO) will emerge with new features of the CCGs. The state-of-the-art review in this paper emphasizes previous strategies for FO detection, source identification, and mitigation. Moreover, the effect of FO is investigated in a power system with CCGs. In its conclusion, this paper also highlights important findings and provides suggestions for subsequent research in this important topic of future power systems. © 2013 IEEE.
- Authors: Surinkaew, Tossaporn , Emami, Koanoush , Shah, Rakibuzzaman , Islam, Syed , Mithulananthan, N.
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Access Vol. 9, no. (2021), p. 150911-150924
- Full Text:
- Reviewed:
- Description: In future power systems, conventional synchronous generators will be replaced by converter controlled-based generations (CCGs), i.e., wind and solar generations, and battery energy storage systems. Thus, the paradigm shift in power systems will lead to the inferior system strength and inertia scarcity. Therefore, the problems of forced oscillation (FO) will emerge with new features of the CCGs. The state-of-the-art review in this paper emphasizes previous strategies for FO detection, source identification, and mitigation. Moreover, the effect of FO is investigated in a power system with CCGs. In its conclusion, this paper also highlights important findings and provides suggestions for subsequent research in this important topic of future power systems. © 2013 IEEE.
Reduced switch multilevel inverter topologies for renewable energy sources
- Sarebanzadeh, Maryam, Hosseinzadeh, Mohammad, Garcia, Cristian, Babaei, Ebrahim, Islam, Syed, Rodriguez, Jose
- Authors: Sarebanzadeh, Maryam , Hosseinzadeh, Mohammad , Garcia, Cristian , Babaei, Ebrahim , Islam, Syed , Rodriguez, Jose
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Access Vol. 9, no. (2021), p. 120580-120595
- Full Text:
- Reviewed:
- Description: This article proposes two generalized multilevel inverter configurations that reduce the number of switching devices, isolated DC sources, and total standing voltage on power switches, making them suitable for renewable energy sources. The main topology is a multilevel inverter that handles two isolated DC sources with ten power switches to create 25 voltage levels. Based on the main proposed topology, two generalized multilevel inverters are introduced to provide flexibility in the design and to minimize the number of elements. The optimal topologies for both extensive multilevel inverters are derived from different design objectives such as minimizing the number of elements (gate drivers, DC sources), achieving a large number of levels, and minimizing the total standing voltage. The main advantages of the proposed topologies are a reduced number of elements compared to those required by other existing multilevel inverter topologies. The power loss analysis and standalone PV application of the proposed topologies are discussed. Experimental results are presented for the proposed topology to demonstrate its correct operation. © 2013 IEEE.
- Authors: Sarebanzadeh, Maryam , Hosseinzadeh, Mohammad , Garcia, Cristian , Babaei, Ebrahim , Islam, Syed , Rodriguez, Jose
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Access Vol. 9, no. (2021), p. 120580-120595
- Full Text:
- Reviewed:
- Description: This article proposes two generalized multilevel inverter configurations that reduce the number of switching devices, isolated DC sources, and total standing voltage on power switches, making them suitable for renewable energy sources. The main topology is a multilevel inverter that handles two isolated DC sources with ten power switches to create 25 voltage levels. Based on the main proposed topology, two generalized multilevel inverters are introduced to provide flexibility in the design and to minimize the number of elements. The optimal topologies for both extensive multilevel inverters are derived from different design objectives such as minimizing the number of elements (gate drivers, DC sources), achieving a large number of levels, and minimizing the total standing voltage. The main advantages of the proposed topologies are a reduced number of elements compared to those required by other existing multilevel inverter topologies. The power loss analysis and standalone PV application of the proposed topologies are discussed. Experimental results are presented for the proposed topology to demonstrate its correct operation. © 2013 IEEE.
Stochastic modeling of the output power of photovoltaic generators in various weather conditions
- Batool, Munira, Islam, Syed, Shahnia, Farhad
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: The intermittency of solar-powered energy sources prompt the uncertainty of load management. The influence of shading (whatever the reason may be) directly diminishes the feasible output power of the photovoltaic (PV) generators. The major causes of shading are the weather condition changes like the clouds, storms, and rains. Thereby, the dispatchable power for a distinct weather condition at an explicit time frame needs to be quantified. The stochastic modeling of a practical PV system has been performed in this paper. A step-by-step MATLAB-based algorithm is developed for tracking of dispatchable power limit using the Monte Carlo Principle. The proposed algorithm describes the weather condition as a function of cloud presence. The prescribed characteristics consist of the solar irradiance and the ambient temperature. The impact of weather changes on the output power of a PV system is evaluated by this algorithm. The results of this research are concluded by realistic data analysis taken from the Australian bureau of meteorology.
- Authors: Batool, Munira , Islam, Syed , Shahnia, Farhad
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text:
- Reviewed:
- Description: The intermittency of solar-powered energy sources prompt the uncertainty of load management. The influence of shading (whatever the reason may be) directly diminishes the feasible output power of the photovoltaic (PV) generators. The major causes of shading are the weather condition changes like the clouds, storms, and rains. Thereby, the dispatchable power for a distinct weather condition at an explicit time frame needs to be quantified. The stochastic modeling of a practical PV system has been performed in this paper. A step-by-step MATLAB-based algorithm is developed for tracking of dispatchable power limit using the Monte Carlo Principle. The proposed algorithm describes the weather condition as a function of cloud presence. The prescribed characteristics consist of the solar irradiance and the ambient temperature. The impact of weather changes on the output power of a PV system is evaluated by this algorithm. The results of this research are concluded by realistic data analysis taken from the Australian bureau of meteorology.
Voxel-based extraction of individual pylons and wires from lidar point cloud data
- Munir, Nosheen, Awrangjeb, Mohammad, Stantic, Bela, Lu, Guojun, Islam, Syed
- Authors: Munir, Nosheen , Awrangjeb, Mohammad , Stantic, Bela , Lu, Guojun , Islam, Syed
- Date: 2019
- Type: Text , Journal article
- Relation: ISPRS annals of the photogrammetry, remote sensing and spatial information sciences Vol. IV-4/W8, no. (2019), p. 91-98
- Full Text:
- Reviewed:
- Description: Extraction of individual pylons and wires is important for modelling of 3D objects in a power line corridor (PLC) map. However, the existing methods mostly classify points into distinct classes like pylons and wires, but hardly into individual pylons or wires. The proposed method extracts standalone pylons, vegetation and wires from LiDAR data. The extraction of individual objects is needed for a detailed PLC mapping. The proposed approach starts off with the separation of ground and non ground points. The non-ground points are then classified into vertical (e.g., pylons and vegetation) and non-vertical (e.g., wires) object points using the vertical profile feature (VPF) through the binary support vector machine (SVM) classifier. Individual pylons and vegetation are then separated using their shape and area properties. The locations of pylons are further used to extract the span points between two successive pylons. Finally, span points are voxelised and alignment properties of wires in the voxel grid is used to extract individual wires points. The results are evaluated on dataset which has multiple spans with bundled wires in each span. The evaluation results show that the proposed method and features are very effective for extraction of individual wires, pylons and vegetation with 99% correctness and 98% completeness.
- Authors: Munir, Nosheen , Awrangjeb, Mohammad , Stantic, Bela , Lu, Guojun , Islam, Syed
- Date: 2019
- Type: Text , Journal article
- Relation: ISPRS annals of the photogrammetry, remote sensing and spatial information sciences Vol. IV-4/W8, no. (2019), p. 91-98
- Full Text:
- Reviewed:
- Description: Extraction of individual pylons and wires is important for modelling of 3D objects in a power line corridor (PLC) map. However, the existing methods mostly classify points into distinct classes like pylons and wires, but hardly into individual pylons or wires. The proposed method extracts standalone pylons, vegetation and wires from LiDAR data. The extraction of individual objects is needed for a detailed PLC mapping. The proposed approach starts off with the separation of ground and non ground points. The non-ground points are then classified into vertical (e.g., pylons and vegetation) and non-vertical (e.g., wires) object points using the vertical profile feature (VPF) through the binary support vector machine (SVM) classifier. Individual pylons and vegetation are then separated using their shape and area properties. The locations of pylons are further used to extract the span points between two successive pylons. Finally, span points are voxelised and alignment properties of wires in the voxel grid is used to extract individual wires points. The results are evaluated on dataset which has multiple spans with bundled wires in each span. The evaluation results show that the proposed method and features are very effective for extraction of individual wires, pylons and vegetation with 99% correctness and 98% completeness.
State estimation within ied based smart grid using kalman estimates
- Rashed, Muhammad, Gondal, Iqbal, Kamruzzaman, Joarder, Islam, Syed
- Authors: Rashed, Muhammad , Gondal, Iqbal , Kamruzzaman, Joarder , Islam, Syed
- Date: 2021
- Type: Text , Journal article
- Relation: Electronics (Switzerland) Vol. 10, no. 15 (2021), p.
- Full Text:
- Reviewed:
- Description: State Estimation is a traditional and reliable technique within power distribution and control systems. It is used for building a topology of the power grid network based on state measurements and current operational state of different nodes & buses. The protection of sensors and measurement units such as Intelligent Electronic Devices (IED) in Central Energy Management System (CEMS) against False Data Injection Attacks (FDIAs) is a big concern to grid operators. These are special kind of cyber-attacks that are directed towards the state & measurement data in such a way that mislead the CEMS into making incorrect decisions and create generation load imbalance. These are known to bypass the traditional bad data detection systems within central estimators. This paper presents the use of an additional novel state estimator based on Kalman filter along with traditional Distributed State Estimation (DSE) which is based on Weighted Least Square (WLS). Kalman filter is a feedback control mechanism that constantly updates itself based on state prediction and state correction technique and shows improvement in the estimates. The additional estimator output is compared with the results of DSE in order to identify anomalies and injection of false data. We evaluated our methodology by simulating proposed technique using MATPOWER over IEEE-14, IEEE-30, IEEE-118, IEEE-300 bus. The results clearly demonstrate the superiority of the proposed method over traditional state estimation. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
- Authors: Rashed, Muhammad , Gondal, Iqbal , Kamruzzaman, Joarder , Islam, Syed
- Date: 2021
- Type: Text , Journal article
- Relation: Electronics (Switzerland) Vol. 10, no. 15 (2021), p.
- Full Text:
- Reviewed:
- Description: State Estimation is a traditional and reliable technique within power distribution and control systems. It is used for building a topology of the power grid network based on state measurements and current operational state of different nodes & buses. The protection of sensors and measurement units such as Intelligent Electronic Devices (IED) in Central Energy Management System (CEMS) against False Data Injection Attacks (FDIAs) is a big concern to grid operators. These are special kind of cyber-attacks that are directed towards the state & measurement data in such a way that mislead the CEMS into making incorrect decisions and create generation load imbalance. These are known to bypass the traditional bad data detection systems within central estimators. This paper presents the use of an additional novel state estimator based on Kalman filter along with traditional Distributed State Estimation (DSE) which is based on Weighted Least Square (WLS). Kalman filter is a feedback control mechanism that constantly updates itself based on state prediction and state correction technique and shows improvement in the estimates. The additional estimator output is compared with the results of DSE in order to identify anomalies and injection of false data. We evaluated our methodology by simulating proposed technique using MATPOWER over IEEE-14, IEEE-30, IEEE-118, IEEE-300 bus. The results clearly demonstrate the superiority of the proposed method over traditional state estimation. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Enhancement of microgrid operation by considering the cascaded impact of communication delay on system stability and power management
- Aghanoori, Navid, Masoum, Mohammad, Abu-Siada, Ahmed, Islam, Syed
- Authors: Aghanoori, Navid , Masoum, Mohammad , Abu-Siada, Ahmed , Islam, Syed
- Date: 2020
- Type: Text , Journal article
- Relation: International Journal of Electrical Power and Energy Systems Vol. 120, no. (2020), p.
- Full Text:
- Reviewed:
- Description: Power management, system stability and communication structure are three key aspects of microgrids (MGs) that have been explored in many research studies. However, the cascaded effect of communication structure on system stability followed by the impact of stability on the power management has not been fully explored in the literature yet and needs more attention. This paper not only explores this cascaded impact, but also provides a comprehensive platform to optimally consider three layers of MG design and operation from this perspective. For generation cost minimization and stability assessment, the proposed platform uses an adaptive particle swarm optimization (PSO) while a new class of data exchange scheme based on IEC 61850 protocol is proposed to reduce the communication time delays among the inverters of distributed generations and the MG control center. This paper also considers the system stability using small-signal model of a MG in a real-time manner as an embedded function in the PSO. In this context investigations have been conducted by modeling an isolated MG with solar farm, fuel cell generator and micro-turbine in MATLAB Simulink. Detailed simulation results indicate the proposed power and stability management method effectively reduces the MG generation cost through maximizing the utilization of the available renewable generations while considering system stability. © 2020 Elsevier Ltd
- Authors: Aghanoori, Navid , Masoum, Mohammad , Abu-Siada, Ahmed , Islam, Syed
- Date: 2020
- Type: Text , Journal article
- Relation: International Journal of Electrical Power and Energy Systems Vol. 120, no. (2020), p.
- Full Text:
- Reviewed:
- Description: Power management, system stability and communication structure are three key aspects of microgrids (MGs) that have been explored in many research studies. However, the cascaded effect of communication structure on system stability followed by the impact of stability on the power management has not been fully explored in the literature yet and needs more attention. This paper not only explores this cascaded impact, but also provides a comprehensive platform to optimally consider three layers of MG design and operation from this perspective. For generation cost minimization and stability assessment, the proposed platform uses an adaptive particle swarm optimization (PSO) while a new class of data exchange scheme based on IEC 61850 protocol is proposed to reduce the communication time delays among the inverters of distributed generations and the MG control center. This paper also considers the system stability using small-signal model of a MG in a real-time manner as an embedded function in the PSO. In this context investigations have been conducted by modeling an isolated MG with solar farm, fuel cell generator and micro-turbine in MATLAB Simulink. Detailed simulation results indicate the proposed power and stability management method effectively reduces the MG generation cost through maximizing the utilization of the available renewable generations while considering system stability. © 2020 Elsevier Ltd
False data detection in a clustered smart grid using unscented Kalman filter
- Rashed, Muhammad, Kamruzzaman, Joarder, Gondal, Iqbal, Islam, Syed
- Authors: Rashed, Muhammad , Kamruzzaman, Joarder , Gondal, Iqbal , Islam, Syed
- Date: 2022
- Type: Text , Journal article
- Relation: IEEE Access Vol. 10, no. (2022), p. 78548-78556
- Full Text:
- Reviewed:
- Description: The smart grid accessibility over the Internet of Things (IoT) is becoming attractive to electrical grid operators as it brings considerable operational and cost efficiencies. However, this in return creates significant cyber security challenges, such as fortification of state estimation data such as state variables against false data injection attacks (FDIAs). In this paper, a clustered partitioning state estimation (CPSE) technique is proposed to detect FDIA by using static state estimation, namely, weighted least square (WLS) method in conjunction with dynamic state estimation using minimum variance unscented Kalman filter (MV-UKF) which improves the accuracy of state estimation. The estimates acquired from the MV-UKF do not deviate like WLS as these are purely based on the previous iteration saved in the transition matrix. The deviation between the corresponding estimations of WLS and MV-UKF are utilised to partition the smart grid into smaller sub-systems to detect FDIA and then identify its location. To validate the proposed detection technique, FIDAs are injected into IEEE 14-bus, IEEE 30-bus, IEEE 118-bus, and IEEE 300-bus distribution feeder using MATPOWER simulation platform. Our results clearly demonstrate that the proposed technique can locate the attack area efficiently compared to other techniques such as chi square. © 2013 IEEE.
- Authors: Rashed, Muhammad , Kamruzzaman, Joarder , Gondal, Iqbal , Islam, Syed
- Date: 2022
- Type: Text , Journal article
- Relation: IEEE Access Vol. 10, no. (2022), p. 78548-78556
- Full Text:
- Reviewed:
- Description: The smart grid accessibility over the Internet of Things (IoT) is becoming attractive to electrical grid operators as it brings considerable operational and cost efficiencies. However, this in return creates significant cyber security challenges, such as fortification of state estimation data such as state variables against false data injection attacks (FDIAs). In this paper, a clustered partitioning state estimation (CPSE) technique is proposed to detect FDIA by using static state estimation, namely, weighted least square (WLS) method in conjunction with dynamic state estimation using minimum variance unscented Kalman filter (MV-UKF) which improves the accuracy of state estimation. The estimates acquired from the MV-UKF do not deviate like WLS as these are purely based on the previous iteration saved in the transition matrix. The deviation between the corresponding estimations of WLS and MV-UKF are utilised to partition the smart grid into smaller sub-systems to detect FDIA and then identify its location. To validate the proposed detection technique, FIDAs are injected into IEEE 14-bus, IEEE 30-bus, IEEE 118-bus, and IEEE 300-bus distribution feeder using MATPOWER simulation platform. Our results clearly demonstrate that the proposed technique can locate the attack area efficiently compared to other techniques such as chi square. © 2013 IEEE.
Blockchain based smart auction mechanism for distributed peer-to-peer energy trading
- Islam, Md Ezazul, Chetty, Madhu, Lim, Suryani, Chadhar, Mehmood, Islam, Syed
- Authors: Islam, Md Ezazul , Chetty, Madhu , Lim, Suryani , Chadhar, Mehmood , Islam, Syed
- Date: 2022
- Type: Text , Conference paper
- Relation: 55th Annual Hawaii International Conference on System Sciences, HICSS 2022, Virtual, online, 3-7 January 2022, Proceedings of the Annual Hawaii International Conference on System Sciences Vol. 2022-January, p. 6013-6022
- Full Text:
- Reviewed:
- Description: Blockchain based framework provides data immutability in a distributed network. In this paper, we investigate the application of blockchain for peer-to-peer (P2P) energy trading. Traditional energy trading systems use simple passing mechanisms and basic pricing methods, thus adversely affect the efficiency and buyers' social welfare. We propose a blockchain based energy trading mechanism that uses smart passing of unspent auction reservations to (a) minimise the time taken to settle an auction (convergence time), (b) maximise the number of auction settlement; and (c) incorporate second-price auction pricing to maximise buyers' social welfare in a distributed double auction environment. The entire mechanism is implemented within Hyperledger Fabric, an open-source blockchain framework, to manage the data and provide smart contracts. Experiments show that our approach minimises the convergence time, maximises the number of auction settlement, and increases the social welfare of buyers compared to existing methods. © 2022 IEEE Computer Society. All rights reserved.
- Authors: Islam, Md Ezazul , Chetty, Madhu , Lim, Suryani , Chadhar, Mehmood , Islam, Syed
- Date: 2022
- Type: Text , Conference paper
- Relation: 55th Annual Hawaii International Conference on System Sciences, HICSS 2022, Virtual, online, 3-7 January 2022, Proceedings of the Annual Hawaii International Conference on System Sciences Vol. 2022-January, p. 6013-6022
- Full Text:
- Reviewed:
- Description: Blockchain based framework provides data immutability in a distributed network. In this paper, we investigate the application of blockchain for peer-to-peer (P2P) energy trading. Traditional energy trading systems use simple passing mechanisms and basic pricing methods, thus adversely affect the efficiency and buyers' social welfare. We propose a blockchain based energy trading mechanism that uses smart passing of unspent auction reservations to (a) minimise the time taken to settle an auction (convergence time), (b) maximise the number of auction settlement; and (c) incorporate second-price auction pricing to maximise buyers' social welfare in a distributed double auction environment. The entire mechanism is implemented within Hyperledger Fabric, an open-source blockchain framework, to manage the data and provide smart contracts. Experiments show that our approach minimises the convergence time, maximises the number of auction settlement, and increases the social welfare of buyers compared to existing methods. © 2022 IEEE Computer Society. All rights reserved.
Domestic load management with coordinated photovoltaics, battery storage and electric vehicle operation
- Das, Narottam, Haque, Akramul, Zaman, Hasneen, Morsalin, Sayidul, Islam, Syed
- Authors: Das, Narottam , Haque, Akramul , Zaman, Hasneen , Morsalin, Sayidul , Islam, Syed
- Date: 2023
- Type: Text , Journal article
- Relation: IEEE Access Vol. 11, no. (2023), p. 12075-12087
- Full Text:
- Reviewed:
- Description: Coordinated power demand management at residential or domestic levels allows energy participants to efficiently manage load profiles, increase energy efficiency and reduce operational cost. In this paper, a hierarchical coordination framework to optimally manage domestic load using photovoltaic (PV) units, battery-energy-storage-systems (BESs) and electric vehicles (EVs) is presented. The bidirectional power flow of EV with vehicle to grid (V2G) operation manages real-time domestic load profile and takes appropriate coordinated action using its controller when necessary. The proposed system has been applied to a real power distribution network and tested with real load patterns and load dynamics. This also includes various test scenarios and prosumer's preferences e.g., with or without EVs, number of EV owners, number of households, and prosumer's daily activities. This is a combined hybrid system for hierarchical coordination that consists of PV units, BES systems and EVs. The system performance was analyzed with different commercial EV types with charging/ discharging constraints and the result shows that the domestic load demand on the distribution grid during the peak period has been reduced significantly. In the end, this proposed system's performance was compared with the prediction-based test techniques and the financial benefits were estimated. © 2013 IEEE.
- Authors: Das, Narottam , Haque, Akramul , Zaman, Hasneen , Morsalin, Sayidul , Islam, Syed
- Date: 2023
- Type: Text , Journal article
- Relation: IEEE Access Vol. 11, no. (2023), p. 12075-12087
- Full Text:
- Reviewed:
- Description: Coordinated power demand management at residential or domestic levels allows energy participants to efficiently manage load profiles, increase energy efficiency and reduce operational cost. In this paper, a hierarchical coordination framework to optimally manage domestic load using photovoltaic (PV) units, battery-energy-storage-systems (BESs) and electric vehicles (EVs) is presented. The bidirectional power flow of EV with vehicle to grid (V2G) operation manages real-time domestic load profile and takes appropriate coordinated action using its controller when necessary. The proposed system has been applied to a real power distribution network and tested with real load patterns and load dynamics. This also includes various test scenarios and prosumer's preferences e.g., with or without EVs, number of EV owners, number of households, and prosumer's daily activities. This is a combined hybrid system for hierarchical coordination that consists of PV units, BES systems and EVs. The system performance was analyzed with different commercial EV types with charging/ discharging constraints and the result shows that the domestic load demand on the distribution grid during the peak period has been reduced significantly. In the end, this proposed system's performance was compared with the prediction-based test techniques and the financial benefits were estimated. © 2013 IEEE.
Reverse blocking over current busbar protection scheme based on IEC 61850 architecture
- Kumar, Shantanu, Abu-Siada, Ahmed, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Abu-Siada, Ahmed , Das, Narottam , Islam, Syed
- Date: 2023
- Type: Text , Journal article
- Relation: IEEE Transactions on Industry Applications Vol. 59, no. 2 (2023), p. 2225-2233
- Full Text:
- Reviewed:
- Description: Substation Automation System (SAS) is currently in a matured state of technology that shall facilitate transformational changes from conventional protection scheme. IEC 61850 protocol is considered as the crux of digital SAS due to its multifunction features that include seamless communication, ability to integrate various intelligent electronic devices, potential for improved real-time condition monitoring, reliable protection, and control of critical electrical assets. Because the application of IEC 61850 in SAS is relatively new and has not fully implemented in many substations yet, further feasibility studies using multivendor equipment to assess its performance under different operating conditions is imperative. In this article, a practical reliable and efficient reverse blocking over current bus bar protection scheme based on IEC 61850 is implemented and tested. Also, a comparison of digital SAS and conventional protection scheme is presented to highlight the superiority of the former one. Experimental results attest the reliability and effectiveness of the proposed digital protection scheme along with the accuracy and security of transmitting data packets using sampled values and generic objective-oriented substation event communication protocols adopted by IEC 61850. © 2022 IEEE.
- Authors: Kumar, Shantanu , Abu-Siada, Ahmed , Das, Narottam , Islam, Syed
- Date: 2023
- Type: Text , Journal article
- Relation: IEEE Transactions on Industry Applications Vol. 59, no. 2 (2023), p. 2225-2233
- Full Text:
- Reviewed:
- Description: Substation Automation System (SAS) is currently in a matured state of technology that shall facilitate transformational changes from conventional protection scheme. IEC 61850 protocol is considered as the crux of digital SAS due to its multifunction features that include seamless communication, ability to integrate various intelligent electronic devices, potential for improved real-time condition monitoring, reliable protection, and control of critical electrical assets. Because the application of IEC 61850 in SAS is relatively new and has not fully implemented in many substations yet, further feasibility studies using multivendor equipment to assess its performance under different operating conditions is imperative. In this article, a practical reliable and efficient reverse blocking over current bus bar protection scheme based on IEC 61850 is implemented and tested. Also, a comparison of digital SAS and conventional protection scheme is presented to highlight the superiority of the former one. Experimental results attest the reliability and effectiveness of the proposed digital protection scheme along with the accuracy and security of transmitting data packets using sampled values and generic objective-oriented substation event communication protocols adopted by IEC 61850. © 2022 IEEE.
Review of the legacy and future of IEC 61850 protocols encompassing substation automation system
- Kumar, Shantanu, Abu-Siada, Ahmed, Das, Narottam, Islam, Syed
- Authors: Kumar, Shantanu , Abu-Siada, Ahmed , Das, Narottam , Islam, Syed
- Date: 2023
- Type: Text , Journal article , Review
- Relation: Electronics (Switzerland) Vol. 12, no. 15 (2023), p.
- Full Text:
- Reviewed:
- Description: Communication protocols play a pivotal role in the substation automation system as they carry critical information related to asset control, automation, protection, and monitoring. Substation legacy protocols run the assets’ bulk data on multiple wires over long distances. These data packets pass through multiple nodes, which makes the identification of the location and type of various malfunctions a challenging and time-consuming task. As downtime of substations is of high importance from a regulatory and compliance point of view, utilities are motivated to revisit the overall scheme and redesign a new system that features flexibility, adaptability, interoperability, and high accuracy. This paper presents a comprehensive review of various legacy protocols and highlights the path forward for a new protocol laid down as per the IEC 61850 standard. The IEC 61850 protocol is expected to be user-friendly, employ fiber optics instead of conventional copper wires, facilitate the application of non-conventional instrument transformers, and connect Ethernet wires to multiple intelligent electronic devices. However, deployment of smart protocols in future substations is not a straightforward process as it requires careful planning, shutdown and foreseeable issues related to interface with proprietary vendor equipment. Along with the technical issues of communication, future smart protocols call for advanced personnel and engineering skills to embrace the new technology. © 2023 by the authors.
- Authors: Kumar, Shantanu , Abu-Siada, Ahmed , Das, Narottam , Islam, Syed
- Date: 2023
- Type: Text , Journal article , Review
- Relation: Electronics (Switzerland) Vol. 12, no. 15 (2023), p.
- Full Text:
- Reviewed:
- Description: Communication protocols play a pivotal role in the substation automation system as they carry critical information related to asset control, automation, protection, and monitoring. Substation legacy protocols run the assets’ bulk data on multiple wires over long distances. These data packets pass through multiple nodes, which makes the identification of the location and type of various malfunctions a challenging and time-consuming task. As downtime of substations is of high importance from a regulatory and compliance point of view, utilities are motivated to revisit the overall scheme and redesign a new system that features flexibility, adaptability, interoperability, and high accuracy. This paper presents a comprehensive review of various legacy protocols and highlights the path forward for a new protocol laid down as per the IEC 61850 standard. The IEC 61850 protocol is expected to be user-friendly, employ fiber optics instead of conventional copper wires, facilitate the application of non-conventional instrument transformers, and connect Ethernet wires to multiple intelligent electronic devices. However, deployment of smart protocols in future substations is not a straightforward process as it requires careful planning, shutdown and foreseeable issues related to interface with proprietary vendor equipment. Along with the technical issues of communication, future smart protocols call for advanced personnel and engineering skills to embrace the new technology. © 2023 by the authors.
Numerical model of cloud-to-ground lightning for pyroCb thunderstorms
- Barman, Surajit, Shah, Rakibuzzaman, Islam, Syed, Kumar, Apurv
- Authors: Barman, Surajit , Shah, Rakibuzzaman , Islam, Syed , Kumar, Apurv
- Date: 2023
- Type: Text , Journal article
- Relation: IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing Vol. 16, no. (2023), p. 8689-8701
- Full Text:
- Reviewed:
- Description: This paper demonstrates a 2-D numerical model to represent two conceptual pyrocumulonimbus (pyroCb) thundercloud structures: i) tilted dipole and ii) tripole structure with enhanced lower positive charge layer, which are hypothesized to explain the occurrence of lightning flashes in pyroCb storms created from severe wildfire events. The presented model considers more realistic thundercloud charge structures to investigate the electrical states and determine surface charge density for identifying potential lightning strike areas on Earth. Simulation results on dipole structure-based pyroCb thunderclouds confirm that the wind-shear extension of its upper positive (UP) charge layer by 2-8 km reduces the electric field and indicates the initiation of negative surface charge density around the earth periphery underneath the anvil cloud. These corresponding lateral extensions have confined the probable striking zone of-CG and +CG lightning within 0-23.5 km and 23.5-30 km in the simulation domain. In contrast, pyroCb thundercloud possessing the tripole structure with enhanced lower positive charge develops a negative electric field at the cloud's bottom part to block the progression of downward negative leader and cause the surface charge density beneath the thundercloud to become negative, which would lead to the formation of +CG flashes. Later, a parametric study is conducted assuming a positive linear correlation between the charge density and aerosol concentration to examine the effect of high aerosol concentration on surface charge density in both pyroCb thunderclouds. The proposed model can be expanded into 3-D to simulate lightning leader movement, aiding wildfire risk management. © 2008-2012 IEEE.
- Authors: Barman, Surajit , Shah, Rakibuzzaman , Islam, Syed , Kumar, Apurv
- Date: 2023
- Type: Text , Journal article
- Relation: IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing Vol. 16, no. (2023), p. 8689-8701
- Full Text:
- Reviewed:
- Description: This paper demonstrates a 2-D numerical model to represent two conceptual pyrocumulonimbus (pyroCb) thundercloud structures: i) tilted dipole and ii) tripole structure with enhanced lower positive charge layer, which are hypothesized to explain the occurrence of lightning flashes in pyroCb storms created from severe wildfire events. The presented model considers more realistic thundercloud charge structures to investigate the electrical states and determine surface charge density for identifying potential lightning strike areas on Earth. Simulation results on dipole structure-based pyroCb thunderclouds confirm that the wind-shear extension of its upper positive (UP) charge layer by 2-8 km reduces the electric field and indicates the initiation of negative surface charge density around the earth periphery underneath the anvil cloud. These corresponding lateral extensions have confined the probable striking zone of-CG and +CG lightning within 0-23.5 km and 23.5-30 km in the simulation domain. In contrast, pyroCb thundercloud possessing the tripole structure with enhanced lower positive charge develops a negative electric field at the cloud's bottom part to block the progression of downward negative leader and cause the surface charge density beneath the thundercloud to become negative, which would lead to the formation of +CG flashes. Later, a parametric study is conducted assuming a positive linear correlation between the charge density and aerosol concentration to examine the effect of high aerosol concentration on surface charge density in both pyroCb thunderclouds. The proposed model can be expanded into 3-D to simulate lightning leader movement, aiding wildfire risk management. © 2008-2012 IEEE.