IR monitoring of absorbent composition and degradation during pilot plant operation
- Authors: Puxty, Graeme , Bennett, Robert , Conway, Will , Webster-Gardiner, Mike , Yang, Qi , Pearson, Pauline , Cottrell, Aaron , Huang, Sanger , Feron, Paul , Reynolds, Alicia , Verheyen, Vincent
- Date: 2020
- Type: Text , Journal article
- Relation: Industrial and Engineering Chemistry Research Vol. 59, no. 15 (2020), p. 7080-7086
- Full Text: false
- Reviewed:
- Description: The monitoring of the absorbent during the operation of CO2 separation processes is a necessary and challenging task. The most common absorbent used is an aqueous amine solution. Traditional approaches to analysis such as titration and chromatography are time-consuming and only provide limited information. This hinders the ability of process operators to rapidly respond to changes in operating conditions. In this work, a combination of infrared (IR) spectroscopy and principle component regression (PCR) analyses have been demonstrated as a rapid and reliable technique to determine the composition of an absorbent during a pilot plant campaign at a brown coal power station. The concentration of amine, a degradation product, CO2, and water was monitored throughout the campaign by a method that provided results in minutes. The results were verified by independent sample analysis using acid-base titration, high-performance liquid chromatography (HPLC), and 13C NMR spectroscopy. It was necessary to use spectral windowing when building the IR-PCR model, but this resulted in a robust and reliable method that has been demonstrated to work in a real-world process environment. © 2019 American Chemical Society.
- Description: The authors wish to acknowledge the financial assistance provided by the Brown Coal Innovation Australia, Ltd., a private member-based company with funding contracts through the Australian National Low Emissions Coal Research and Development, Ltd. (ANLEC R&D) and the Victorian State Government. The work described here was made possible through the PICA project, a collaboration between AGL Loy Yang, IHI, and CSIRO that aims to advance post-combustion CO 2 -capture technology in Australia.
Technical evaluation of post-combustion CO2 capture and hydrogen production industrial symbiosis
- Authors: Ghayur, Adeel , Verheyen, Vincent
- Date: 2018
- Type: Text , Journal article
- Relation: International Journal of Hydrogen Energy Vol. 43, no. 30 (2018), p. 13852-13859
- Full Text:
- Reviewed:
- Description: The aim of this study is to develop an industrial ecosystem whereby wastes/products from a Post-combustion CO2 Capture (PCC) plant are utilised in a hydrogen biorefinery. Subsequently, five hydrogen biorefinery models are developed that use PCC's model amine i.e. monoethanolamine (MEA) as a nitrogen source during microbial hydrogen production and CO2 as a process chemical. Technical evaluations of the five case models are carried out to identify the ones that maximise value by multiproduct generation from biomass and fulfil total/partial parasitic energy demand. The case meeting these criteria, produces 3.1t of succinylated lignin adhesive, 4.9t of dry compost and 2744 kWh of electricity from 10t (dry) of sawdust feedstock, daily. Its daily power and heat duties stand at 3906 kWh and 52.1 GJ respectively. Simulations also demonstrate biohydrogen's potential as an energy storage vector for peak/backup power with an annual 1001.4 MWh of power storage capacity from 10t/d feedstock. © 2018 Hydrogen Energy Publications LLC
Quantification of aqueous monoethanolamine concentration by gas chromatography for postcombustion capture of
- Authors: Reynolds, Alicia , Verheyen, Vincent , Adeloju, Samuel , Chaffee, Alan , Meuleman, Erik
- Date: 2014
- Type: Text , Journal article
- Relation: Industrial and Engineering Chemistry Research Vol. 53, no. 12 (2014), p. 4805-4811
- Full Text: false
- Reviewed:
- Description: The availability of reliable analytical methods for measuring amine concentrations is necessary for optimum operation of aqueous amine CO 2 separation systems being employed for postcombustion capture (PCC) of CO2. A GC-FID (gas chromatography with flame ionization detection) method is described for the reliable quantification of 30% (w/w) monoethanolamine (MEA) in severely degraded solvent samples. The observation of intermittent splitting of the MEA peak was a major concern with this approach. The use of a wide-bore column led to improved MEA peak resolution and peak shape. The reliability and robustness of the GC-FID method were assessed by analyzing degraded 30% (w/w) MEA solvent samples from CSIRO's pilot plant at AGL's Loy Yang power station in Victoria, Australia. The results were compared with those obtained by titration and total organic carbon (TOC) measurements of the same samples. The MEA concentrations obtained by the GC-FID and titration methods were statistically similar. In contrast, the MEA concentrations calculated from TOC were consistently higher than those obtained by both GC-FID and titration. © 2014 American Chemical Society.