A comprehensive analyses of aging characteristics of oil-paper insulation system in HVDC converter transformers
- Authors: Cui, Huize , Yang, Liuqing , Zhu, Yuanwei , Li, Shengtao , Abu-Siada, Ahmed , Islam, Syed
- Date: 2020
- Type: Text , Journal article
- Relation: IEEE Transactions on Dielectrics and Electrical Insulation Vol. 27, no. 5 (2020), p. 1707-1714
- Full Text: false
- Reviewed:
- Description: This paper investigates the dissolved gases evolution in transformer oil under combined DC/AC electrical-Thermal stress. Dissolved gases detected in transformer aged insulation oil reveal that oil under AC electric field combined with thermal stress can produce more dissolved gases than oil under DC electric field with thermal stress but less than the gases produced in oil under distorted AC or combined AC/DC voltage stress. This is attributed to the divergent migration properties of the charged components under different types of electric fields. To further understand this behavior, carrier recombination coefficient is proposed to explain the oil DGA results under various aging stresses. Results show that diagnostic parameters such as breakdown voltage, oil interfacial tension, and moisture content in pressboard should be used along with DGA results in order to accurately diagnose the insulation condition within converter transformers that impose a combined AC/DC voltage stress on the insulation system. © 1994-2012 IEEE.
- Description: This work has been supported by the National Key Research and Development Program of China (2017YFB0902705), State Key Laboratory of Electrical Insulation and Power Equipment (EIPE20210), the National Natural Science Foundation of China (51907148), the Youth Fund of State Key Laboratory of Electrical Insulation and Power Equipment (EIPE19308), the Foundation Project of State Grid in Shaanxi province section, China (SGSNKY00SPJS1900302). The authors thank the Natural Science Basic Research Plan in Shaanxi Province of China (2019JQ-070).
A Fast and Reliable Blocked Bus Bar Protection Scheme Leveraging on Sampled Value and GOOSE Protection based on IEC 61850 Architecture
- Authors: Kumar, Shantanu , Abu-Siada, Ahmed , Das, Narottam , Islam, Syed
- Date: 2021
- Type: Text , Conference paper
- Relation: 31st Australasian Universities Power Engineering Conference, AUPEC 2021, Virtual, Online 26 to 30 September 2021, Proceedings of 2021 31st Australasian Universities Power Engineering Conference, AUPEC 2021
- Full Text: false
- Reviewed:
- Description: Substation Automation System (SAS) is in a matured state and promises to replace conventional protection scheme. It has created a new paradigm in its application for future smart grids. The multifunction features of IEC 61850 facilitate this technology to reliably monitor, protect and control critical assets. Mostly agree, the intelligent electronic devices (IEDs) and substation automation features have the same effect as 'html' had in developing web technology on IT system in 1990's. However, in order to be acceptable completely, this technology needs to gain confidence of end user, it needs to be researched further using multivendor equipment and experimented in a network comprising of complex secondary protection schemes. In this paper, a practical Blocked Busbar Protection (BBP) scheme have been implemented and tested for a single bus bar scheme, leveraging on Sampled Values (SV) and Generic Object Oriented Substation Event (GOOSE) at laboratory to prove its reliability and improvement in technology. This experiment has been carried out for three scenarios in a simulated substation network related to a process plant industry. Furthermore, this laboratory-based experiment with multivendor IEDs evaluated performance of an Ethernet and FO based process bus network to validate overall performance of BBP protection scheme. It concluded with a comparison between digital and conventional protection scheme with recommendation for future applications. © 2021 IEEE.
A Magnetic linked modular cascaded multilevel converter for medium voltage grid applications
- Authors: Hasan,Md Mubashwar , Islam, Syed , Abu-Siada, Ahmed , Islam, Rabiul Md
- Date: 2019
- Type: Text , Conference proceedings
- Relation: 2019 29th Australasian Universities Power Engineering Conference (AUPEC); Nadi, Fiji; 26-29 November 2019
- Full Text: false
- Reviewed:
- Description: One of the key advantages of cascaded multilevel inverters (CMLI) is their ability to generate medium voltage output by using low voltage rated circuit components. For this reason, CMLI has been given much attention in renewable and industrial applications. However, in spite CMLI advantages, balanced input dc voltage management at the cascaded cells is still considered one of the main drawbacks, which limits its straightforward applications. Moreover, galvanic isolation between the input dc supply and the inverter output voltage is essential for grid-connected application. In such case, a step-up transformer is utilized between the inverter output terminals and the grid. This solution incurs additional cost, increases implementation size, weight and maintenance. In this paper, a CMLI is proposed for medium voltage applications by utilizing high frequency magnetic link to ensure galvanic isolation without the need to a conventional step-up transformer as per the current practice. 3 rd harmonic-injected sine pulse width modulation strategy is adopted as a switching controller for the proposed cascaded inverter that is implemented and tested. Experimental results attest the simulation results and confirm the feasibility of the proposed inverter
A new cascaded multilevel inverter topology with galvanic isolation
- Authors: Hasan, Mubashwar , Abu-Siada, Ahmed , Islam, Syed , Dahidah, Mohamed
- Date: 2018
- Type: Text , Journal article
- Relation: IEEE Transactions on Industry Applications Vol. 54, no. 4 (2018), p. 3463-3472
- Full Text:
- Reviewed:
- Description: IEEE This paper presents a new compact three-phase cascaded multilevel inverter (CMLI) topology with reduced device count and high frequency magnetic link. The proposed topology overcomes the predominant limitation of separate DC power supplies, which CMLI always require. The high frequency magnetic link also provides a galvanic isolation between the input and output sides of the inverter, which is essential for various grid-connected applications. The proposed topology utilizes an asymmetric inverter configuration that consists of cascaded H-bridge cells and a conventional three-phase two-level inverter. A toroidal core is employed for the high frequency magnetic link to ensure compact size and high-power density. Compared with counterpart CMLI topologies available in the literatures, the proposed inverter has the advantage of utilizing the least number of power electronic components without compromising the overall performance, particularly when a high number of output voltage levels is required. The feasibility of the proposed inverter is confirmed through extensive simulation and experimentally validated studies.
A new control approach to improve the overall performance of DFIG-based WECS
- Authors: Khamaira, Mahmoud , Abu-Siada, Ahmed , Islam, Syed , Masoum, Mohammad
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 24th Australasian Universities Power Engineering Conference, AUPEC 2014; Perth, Australia; 28th September-1st October 2014 p. 1-5
- Full Text: false
- Reviewed:
- Description: Doubly Fed Induction Generators (DFIGs) are currently extensively used in variable speed wind power plants due to their superior advantages that include reduced converter rating, low cost, reduced losses, easy implementation of power factor correction schemes, variable speed operation and four quadrants active and reactive power control capabilities. On the other hand, DFIG sensitivity to grid disturbances, especially for voltage sags represents the main disadvantage of the equipment. In this paper, a coil is proposed to be integrated within the DFIG converters to improve the overall performance of a DFIG-based wind energy conversion system (WECS). A proportional integral (PI) controller to control the charging and discharging of the coil is introduced. Simulation results reveal the effectiveness of the proposed topology in improving the overall performance of the WECS under study.
A new data driven long-term solar yield analysis model of photovoltaic power plants
- Authors: Ray, Biplob , Shah, Rakibuzzaman , Islam, Md Rabiul , Islam, Syed
- Date: 2020
- Type: Text , Journal article
- Relation: IEEE Access Vol. 8, no. (2020), p. 136223-136233
- Full Text:
- Reviewed:
- Description: Historical data offers a wealth of knowledge to the users. However, often restrictively mammoth that the information cannot be fully extracted, synthesized, and analyzed efficiently for an application such as the forecasting of variable generator outputs. Moreover, the accuracy of the prediction method is vital. Therefore, a trade-off between accuracy and efficacy is required for the data-driven energy forecasting method. It has been identified that the hybrid approach may outperform the individual technique in minimizing the error while challenging to synthesize. A hybrid deep learning-based method is proposed for the output prediction of the solar photovoltaic systems (i.e. proposed PV system) in Australia to obtain the trade-off between accuracy and efficacy. The historical dataset from 1990-2013 in Australian locations (e.g. North Queensland) are used to train the model. The model is developed using the combination of multivariate long and short-term memory (LSTM) and convolutional neural network (CNN). The proposed hybrid deep learning (LSTM-CNN) is compared with the existing neural network ensemble (NNE), random forest, statistical analysis, and artificial neural network (ANN) based techniques to assess the performance. The proposed model could be useful for generation planning and reserve estimation in power systems with high penetration of solar photovoltaics (PVs) or other renewable energy sources (RESs). © 2013 IEEE.
A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis
- Authors: Abu-Siada, Ahmed , Hmood, Sdood , Islam, Syed
- Date: 2013
- Type: Text , Journal article
- Relation: IEEE Transactions on Dielectrics and Electrical Insulation Vol. 20, no. 6 (2013), p. 2343-2349
- Full Text:
- Reviewed:
- Description: Dissolved gas analysis (DGA) of transformer oil is one of the most effective power transformer condition monitoring tools. There are many interpretation techniques for DGA results however all these techniques rely on personnel experience more than analytical formulation. As a result, various interpretation techniques do not necessarily lead to the same conclusion for the same oil sample. Furthermore, significant number of DGA results fall outside the proposed codes of the current based-ratio interpretation techniques and cannot be diagnosed by these methods. Moreover, ratio methods fail to diagnose multiple fault conditions due to the mixing up of produced gases. To overcome these limitations, this paper introduces a new fuzzy logic approach to reduce dependency on expert personnel and to aid in standardizing DGA interpretation techniques. The approach relies on incorporating all existing DGA interpretation techniques into one expert model. DGA results of 2000 oil samples that were collected from different transformers of different rating and different life span are used to establish the model. Traditional DGA interpretation techniques are used to analyze the collected DGA results to evaluate the consistency and accuracy of each interpretation technique. Results of this analysis were then used to develop the proposed fuzzy logic model.
A new technique to measure interfacial tension of transformer oil using UV-Vis spectroscopy
- Authors: Abu Bakar, Norazhar , Abu-Siada, Ahmed , Islam, Syed , El-Naggar, Mohammed
- Date: 2015
- Type: Text , Journal article
- Relation: IEEE Transactions on Dielectrics and Electrical Insulation Vol. 22, no. 2 (2015), p. 1275-1282
- Full Text:
- Reviewed:
- Description: Interfacial tension (IFT) and acid numbers of insulating oil are correlated with the number of years that a transformer has been in service and are used as a signal for transformer oil reclamation. Oil sampling for IFT measurement calls for extra precautions due to its high sensitivity to various oil parameters and environmental conditions. The current used technique to measure IFT of transformer oil is relatively expensive, requires an expert to conduct the test and it takes long time since the extraction of oil sample, sending it to external laboratory and getting the results back. This paper introduces a new technique to estimate the IFT of transformer oil using ultraviolet-to-visible (UV-Vis) spectroscopy. UV-Vis spectral response of transformer oil can be measured instantly with relatively cheap equipment, does not need an expert person to conduct the test and has the potential to be implemented online. Results show that there is a good correlation between oil spectral response and its IFT value. Artificial neural network (ANN) approach is proposed to model this correlation.
A new topology for doubly fed induction generator to improve the overall performance of wind energy conversion system
- Authors: Khamaira, Mahmoud , Abu-Siada, Ahmed , Islam, Syed , Masoum, Mohammad
- Date: 2014
- Type: Text , Journal article
- Relation: Elixir International Journal: Electrical Engineering Vol. 73, no. (2014), p. 26432-26435
- Full Text:
- Reviewed:
- Description: Doubly Fed Induction Generators (DFIGs) are currently extensively used in variable speed wind power plants due to their superior advantages that include reduced converter rating, low cost, reduced losses, easy implementation of power factor correction schemes, variable speed operation and four quadrants active and reactive power control capabilities. On the other hand, DFIG sensitivity to grid disturbances, especially for voltage sags represents the main disadvantage of the equipment. In this paper, a coil is proposed to be integrated within the DFIG converters to improve the overall performance of a DFIGbased wind energy conversion system (WECS). The charging and discharging of the coil are controlled by controlling the duty cycle of the switches of the dc-dc chopper. Simulation results reveal the effectiveness of the proposed topology in improving the overall performance of the WECS system under study.
A novel concept for three-phase cascaded multilevel inverter topologies
- Authors: Hasan, Mubashwar , Abu-Siada, Ahmed , Islam, Syed , Muyeen, S.
- Date: 2018
- Type: Text , Journal article
- Relation: Energies Vol. 11, no. 2 (2018), p. 1-16
- Full Text:
- Reviewed:
- Description: One of the key challenges in multilevel inverters (MLIs) design is to reduce the number of components used in the implementation while maximising the number of output voltage levels. This paper proposes a new concept that facilitates a device count reduction technique of existing cascaded MLIs. Moreover, the proposed concept can be utilised to extend existing single phase cascaded MLI topologies to three-phase structure without tripling the number of semiconductor components and input dc-supplies as per the current practice. The new generalized concept involves two stages; namely, cascaded stage and phase generator stage. The phase generator stage is a combination of a conventional three-phase two level inverter and three bi-directional switches while the cascaded stage can employ any existing cascaded topology. A laboratory prototype model is built and extensive experimental analyses are conducted to validate the feasibility of the proposed cascaded MLI concept.
A novel generalized concept for three phase cascaded multilevel inverter topologies
- Authors: Hasan,Md Mubashwar , Abu-Siada, Ahmed , Islam, Syed , Muyeen, S
- Date: 2017
- Type: Text , Conference proceedings
- Relation: 9th Annual IEEE Green Technologies Conference (GreenTech 2017); Denver, CO; 29th-21st March, 2017 p. 110-117
- Full Text: false
- Reviewed:
- Description: Many new cascaded multilevel inverter (MLI) topologies have recently been proposed and published in the literature. All proposed topologies demand significant amount of semiconductor components and input dc supplies, which is considered the main drawback for the implementation of three phase cascaded MLIs. This paper proposes a new generalized concept that could be employed within any existing cascaded MLI topology in order to reduce its size in terms of device count including semiconductor switches, diodes, and dc power supplies. The new generalized concept involves two stages namely, cascaded stage (CS) and phase generator stage (PGS). The PGS stage is a combination of conventional three phase two level inverter (CTPTLI) and three bidirectional (BD) switches, while the cascaded stage can be modified using any existing cascaded topology. The proposed concept is validated through extensive simulation and experimental analyses. Results show the capability of the proposed technique in reducing device count of the existing topologies while maintaining its performance.
A preliminary study on conversion efficiency improvement of a multi-junction PV cell with MPPT
- Authors: Das, Narottam , Wongsodihardjo, Hendy , Islam, Syed
- Date: 2016
- Type: Text , Book chapter
- Relation: Smart Power Systems and Renewable Energy System Integration (part of the Studies in Systems, Decision and Control book series) Chapter 4 p. 49-73
- Full Text: false
- Reviewed:
- Description: This chapter presents a preliminary study conducted to improve photovoltaic (PV) cell conversion efficiency using MATLAB/Simulink platform. The study uses multi-junction solar cell and investigates the maximum performance compared with a conventional silicon PV cell. Maximum Power Point Tracker (MPPT) is applied to assess the conversion efficiency of the PV system. Study integrates thermoelectric generator (TEG) with PV modules because the PV cells work by converting high frequency irradiation where as a TEG has the ability to convert wasted low frequency heat to the electricity. The combination delivers more power and contributes to enhance the conversion efficiency of a PV system. The simulation results show that a tandem cell can provide a considerable higher power with a conventional PV cell operation.
A review of dissolved gas analysis measurement and interpretation techniques
- Authors: Abu Bakar, Norazhar , Abu-Siada, Ahmed , Islam, Syed
- Date: 2014
- Type: Text , Journal article
- Relation: IEEE Electrical Insulation Magazine Vol. 30, no. 3 (2014), p. 39-49
- Full Text: false
- Reviewed:
- Description: Dissolved gas analysis (DGA) is used to assess the condition of power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. DGA has gained worldwide acceptance as a method for the detection of incipient faults in transformers.
A review on chemical diagnosis techniques for transformer paper insulation degradation
- Authors: Abu Bakar, Norazhar , Abu Siada, Ahmed , Islam, Syed
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 Australasian Universities Power Engineering Conference, AUPEC 2013; Hobart, Australia; 29th September-3rd October 2013 p. 1-6
- Full Text:
- Reviewed:
- Description: Energized parts within power transformer are isolated using paper insulation and are immersed in insulating oil. Hence, transformer oil and paper insulation are essential sources to detect incipient and fast developing power transformer faults. Several chemical diagnoses techniques are developed to examine the condition of paper insulation such as degree of polymerization, carbon oxides, furanic compounds and methanol. The principle and limitation of these diagnoses are discussed and compared in this paper.
A three dimensional imaging-based framework for planning maxillomandibular advancement surgery for the treatment of obstructive sleep apnoea
- Authors: Islam, Syed , Goonewardene, Mithran , Bennamoun, Mohammed , Lucey, Anthony , Farella, Mauro , Abduo, Jaafar , Cisonni, Julien
- Date: 2013
- Type: Text , Conference proceedings , Conference paper
- Relation: 2013 4th World Congress on Software Engineering, WCSE 2013; Hong Kong, China; 3rd-4th December 2013 p. 301-306
- Full Text: false
- Reviewed:
- Description: Obstructive Sleep Apnoea (OSA), a sleeping disorder, is a serious health issue with significant public health implications. Due to the interrupted sleep, OSA patients suffer with excessive day-time sleepiness, fatigue and other health complexities that lead to on-road and work-related accidents and incur billions of dollars per year. Traditionally, treatment of OSA begins with nasal continuous positive airway pressure (CPAP). Alternatively, Mandibular Repositioning Appliances or surgical interventions can be used. Although Maxillomandibular Advancement (MMA) surgery is often advised as the last line of treatment due to the expense and significant changes in the facial appearance, it is the only permanent solution to OSA with a definitive outcome especially for the patients with significant facial deformation or anomalies. In this article, three dimensional (3D) image-guided predictive algorithms are proposed to improve the treatment planning and overall outcome of the MMA surgery. 3D analysis of the facial surface data and Computational Biomechanics-based 3D modelling of airway segmented from Cone Beam Computed Tomography (CBCT) data are proposed to predict the required physiological changes to ensure optimal air-flow through the airway. Moreover, 3D Computer Graphics-based techniques are proposed to visualise and demonstrate the expected facial outcomes to inform patients and surgeons prior to this non-reversible surgery.
A three-phase half-bridge cascaded inverter with reduced number of input DC supply
- Authors: Hasan, Mubashwar , Abu-Siada, Ahmed , Islam, Syed , Muyeen, S.
- Date: 2017
- Type: Text , Conference proceedings
- Relation: 2017 Australasian Universities Power Engineering Conference, AUPEC 2017; Melbourne, Australia; 19th-22nd November 2017 Vol. 2017, p. 1-7
- Full Text: false
- Reviewed:
- Description: Cascaded multilevel inverters (MLI) have recently received much attention due to its ability to perform well in various high voltage and high power applications with high efficiency. Cascaded inverters are able to generate high voltage output by utilizing a number of low voltage DC supplies and switches of low blocking voltage rating, which make cascaded MLI a cost effective choice for high voltage/power applications. The main drawback of cascaded MLI is the requirement of large number of isolated DC sources particularly, for three phase applications where the number of required input DC sources is three times that of single phase structure. In addition to the extra cost it will incur, the use of large number of DC supplies within the inverter will significantly increase its physical size, and complicate the management of such large number of DC sources. This paper presents a new topology for three phase MLI with a minimum number of input DC supplies. Symmetric and asymmetric input DC supply modes are developed for the proposed topology. Simulation and experimental results are provided to assess the performance of the proposed MLI topology.
A travelling wave detector based fault location device and data recorder for medium voltage distribution systems
- Authors: Jahromi, Ali , Wolfs, Peter , Islam, Syed
- Date: 2016
- Type: Text , Conference proceedings , Conference paper
- Relation: 2016 Australasian Universities Power Engineering Conference, AUPEC 2016; Brisbane, Australia; 25th-28th September 2016 p. 1-5
- Full Text: false
- Reviewed:
- Description: This paper presents a hardware design for a Travelling Wave (TW) Detector and data recorder for a three phase Medium Voltage (MV) distribution network. The proposed pole mounted platform consists of a capacitively coupled receiver system, a GPS receiver and a Texas Instruments Delfino 28377 processor based travelling wave detection unit. The data recording system uses an Intel Atom base single board computer, a four channel 10Ms/s analogue to digital converter card along with Wi-Fi and GORS communications links. The proposed system is capable of recording three phase voltages simultaneously with the ability to trigger remotely. The platform is mounted in an IP56 enclosure and can be mounted on the MV distribution poles. The paper provides a brief review of hardware and software developed for the TW detector.
A unified model predictive voltage and current control for microgrids with distributed fuzzy cooperative secondary control
- Authors: Shan, Yinghao , Hu, Jiefeng , Chan, Ka , Islam, Syed
- Date: 2021
- Type: Text , Journal article
- Relation: IEEE Transactions on Industrial Informatics Vol. 17, no. 12 (DEC 2021), p. 8024-8034
- Full Text: false
- Reviewed:
- Description: A microgrid formed by a cluster of parallel distributed generation (DG) units is capable of operating in either islanded mode or grid-connected mode. Traditionally, by using model predictive control algorithms, these two operation modes can be achieved with two separate and different cost functions, which brings in control complexity and hence, compromises system reliability. In this article, a unified model predictive voltage and current control strategy is proposed for both islanded and grid-connected operations and their smooth transition. The cost function is kept unified with voltage and current taken into account without altering the control architecture. It can be used for high-quality voltage supply at the primary control level and for bidirectional power flow at the tertiary control level. In addition, by only using DGs' own and neighboring information, a distributed fuzzy cooperative algorithm is developed at the secondary layer to mitigate the voltage and frequency deviations inherent from the power droop. The fuzzy controller can optimize the secondary control coefficients for further voltage quality improvement. Comprehensive tests under various scenarios demonstrate the merits of the proposed control strategy over traditional methods.
Alleviating post-contingency congestion risk of wind integrated systems with dynamic line ratings
- Authors: Banerjee, Binayak , Jayaweera, Dilan , Islam, Syed
- Date: 2014
- Type: Text , Conference proceedings , Conference paper
- Relation: 24th Australasian Universities Power Engineering Conference, AUPEC 2014; Perth, Australia; 28th September-1st October 2014 p. 1-6
- Full Text: false
- Reviewed:
- Description: One of the factors hindering the large scale integration of wind power is the post contingency congestion of a network due to limited availability of network capacity and auxiliary constraints. Under such conditions, the network operators can potentially request a curtailment of wind farm output if the remedial strategies fail. The paper investigates this problem in detail and proposes a mathematical framework to capture the post contingency spare capacity of network assets that is required to limit the wind curtailment. The proposed approach incorporates stochastic variation in asset thermal rating; models network congestion, and quantifies the risk of congestion using an extended version of conic-quadratic programming based optimization. The uniqueness of the proposed mathematical model is that it converts conventional thermal constraints to dynamic constraints by using a discretized stochastic penalty function with quadratic approximation of constraint relaxation penalty. The results suggest that the wind utilization can be maximized if the networks are operated 30-50% less than the nominal rating of the assets.
An experimental thermographic safety audit focusing on temperature rise vs load in electrical installations in a Bangladesh garments factory
- Authors: Islam, Syed , Huque, Mozammel , Khan, Liakot , Hossain, Imran
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 4th International Conference on Advances in Electrical Engineering, ICAEE 2017; Dhaka, Bangladesh; 28th-30th September 2017 Vol. 2018, p. 561-564
- Full Text: false
- Reviewed:
- Description: Thermographic scanning of electrical installations is sometimes conducted as part of electrical safety audits. This scanning is mostly considered based on the present temperature identified on a particular device or location and according to a pre-specified temperature category. But in most of the cases the recommended temperature of the particular devices cannot be considered during temperature categorization. There are many electrical audits using Thermographic scanning and recommend solution based on normal category of temperature rather than manufacturer's suggestion or specified standard for particular electrical device. Now a days, thermographic scanning is being used in Readymade Garments (RMG) industries in Bangladesh in such simple way where details analysis are not in practice and hence exact recommendation is absent in reports. The importance of this topic is focused on the 4.2 million people working in more than 5,000 factories in Bangladesh, where 80% of the fire incident are caused by inappropriate electrical installation or short circuits (as per Fire Service and Civil Defense statistics of Bangladesh). Recently many violent industrial accidents caused death of more than 1,500 people in the last 3 years. Among these, majority of the incidents were due to unsafe electrical system and inappropriate maintenance. The paper will further explore the importance of thermal scanning on electrical devices and compare the temperature considering manufacturer's recommendation for identifying system errors. The paper is written based on previously published recommendations and based on conducting an experimental sample audit aimed to develop a thermography based auditing standard. Based on the statistical and systematic analysis of the obtained data (e.g. temperature values, visual abnormalities, comparative differences) the paper will further discuss the possible area(s) that can be improved by introducing the thermal reports for the safety audits. This paper is aimed to develop an auditing structure proposed to implement identified areas within a standard electrical safety audit process.