A computational model to investigate the influence of electrode lengths on the single probe bipolar radiofrequency ablation of the liver
- Authors: Cheong, Jason , Yap, Shelley , Ooi, Ean Tat , Ooi, Ean Hin
- Date: 2019
- Type: Text , Journal article
- Relation: Computer Methods and Programs in Biomedicine Vol. 176, no. (2019), p. 17-32
- Full Text: false
- Reviewed:
- Description: Background and objectives: Recently, there have been calls for RFA to be implemented in the bipolar mode for cancer treatment due to the benefits it offers over the monopolar mode. These include the ability to prevent skin burns at the grounding pad and to avoid tumour track seeding. The usage of bipolar RFA in clinical practice remains uncommon however, as not many research studies have been carried out on bipolar RFA. As such, there is still uncertainty in understanding the effects of the different RF probe configurations on the treatment outcome of RFA. This paper demonstrates that the electrode lengths have a strong influence on the mechanics of bipolar RFA. The information obtained here may lead to further optimization of the system for subsequent uses in the hospitals. Methods: A 2D model in the axisymmetric coordinates was developed to simulate the electro-thermophysiological responses of the tissue during a single probe bipolar RFA. Two different probe configurations were considered, namely the configuration where the active electrode is longer than the ground and the configuration where the ground electrode is longer than the active. The mathematical model was first verified with an existing experimental study found in the literature. Results: Results from the simulations showed that heating is confined only to the region around the shorter electrode, regardless of whether the shorter electrode is the active or the ground. Consequently, thermal coagulation also occurs in the region surrounding the shorter electrode. This opened up the possibility for a better customized treatment through the development of RF probes with adjustable electrode lengths. Conclusions: The electrode length was found to play a significant role on the outcome of single probe bipolar RFA. In particular, the length of the shorter electrode becomes the limiting factor that influences the mechanics of single probe bipolar RFA. Results from this study can be used to further develop and optimize bipolar RFA as an effective and reliable cancer treatment technique. (C) 2019 Elsevier B.V. All rights reserved.
Bipolar radiofrequency ablation treatment of liver cancer employing monopolar needles : a comprehensive investigation on the efficacy of time-based switching
- Authors: Yap, Shelley , Ooi, Ean , Foo, Ji , Ooi, Ean Tat
- Date: 2021
- Type: Text , Journal article
- Relation: Computers in Biology and Medicine Vol. 131, no. (2021), p.
- Full Text: false
- Reviewed:
- Description: Radiofrequency ablation (RFA) is a thermal ablative treatment method that is commonly used to treat liver cancer. However, the thermal coagulation zone generated using the conventional RFA system can only successfully treat tumours up to 3 cm in diameter. Switching bipolar RFA has been proposed as a way to increase the thermal coagulation zone. Presently, the understanding of the underlying thermal processes that takes place during switching bipolar RFA remains limited. Hence, the objective of this study is to provide a comprehensive understanding on the thermal ablative effects of time-based switching bipolar RFA on liver tissue. Five switch intervals, namely 50, 100, 150, 200 and 300 s were investigated using a two-compartment 3D finite element model. The study was performed using two pairs of RF electrodes in a four-probe configuration, where the electrodes were alternated based on their respective switch interval. The physics employed in the present study were verified against experimental data from the literature. Results obtained show that using a shorter switch interval can improve the homogeneity of temperature distribution within the tissue and increase the rate of temperature rise by delaying the occurrence of roll-off. The coagulation volume obtained was the largest using switch interval of 50 s, followed by 100, 150, 200 and 300 s. The present study demonstrated that the transient thermal response of switching bipolar RFA can be improved by using shorter switch intervals. © 2021 Elsevier Ltd
Comparisons between impedance-based and time-based switching bipolar radiofrequency ablation for the treatment of liver cancer
- Authors: Yap, Shelley , Ooi, Ean , Foo, Ji , Ooi, Ean Tat
- Date: 2021
- Type: Text , Journal article
- Relation: Computers in Biology and Medicine Vol. 134, no. (2021), p.
- Full Text: false
- Reviewed:
- Description: Switching bipolar radiofrequency ablation (bRFA) is a cancer treatment technique that activates multiple pairs of electrodes alternately based on a predefined criterion. Various criteria can be used to trigger the switch, such as time (ablation duration) and tissue impedance. In a recent study on time-based switching bRFA, it was determined that a shorter switch interval could produce better treatment outcome than when a longer switch interval was used, which reduces tissue charring and roll-off induced cooling. In this study, it was hypothesized that a more efficacious bRFA treatment can be attained by employing impedance-based switching. This is because ablation per pair can be maximized since there will be no interruption to RF energy delivery until roll-off occurs. This was investigated using a two-compartment 3D computational model. Results showed that impedance-based switching bRFA outperformed time-based switching when the switch interval of the latter is 100 s or higher. When compared to the time-based switching with switch interval of 50 s, the impedance-based model is inferior. It remains to be investigated whether the impedance-based protocol is better than the time-based protocol for a switch interval of 50 s due to the inverse relationship between ablation and treatment efficacies. It was suggested that the choice of impedance-based or time-based switching could ultimately be patient-dependent. © 2021 Elsevier Ltd
The effects of electrical and thermal boundary condition on the simulation of radiofrequency ablation of liver cancer for tumours located near to the liver boundary
- Authors: Ooi, Ean Hin , Lee, Khiy , Yap, Shelley , Khattab, Mahmoud , Liao, Iman , Ooi, Ean Tat , Foo, Ji , Nair, Shalini , Ali, Ahmad
- Date: 2019
- Type: Text , Journal article
- Relation: Computers in Biology and Medicine Vol. 106, no. (2019), p. 12-23
- Full Text: false
- Reviewed:
- Description: Effects of different boundary conditions prescribed across the boundaries of radiofrequency ablation (RFA) models of liver cancer are investigated for the case where the tumour is at the liver boundary. Ground and Robin-type conditions (electrical field) and body temperature and thermal insulation (thermal field) conditions are examined. 3D models of the human liver based on publicly-available CT images of the liver are developed. An artificial tumour is placed inside the liver at the boundary. Simulations are carried out using the finite element method. The numerical results indicated that different electrical and thermal boundary conditions led to different predictions of the electrical potential, temperature and thermal coagulation distributions. Ground and body temperature conditions presented an unnatural physical conditions around the ablation site, which results in more intense Joule heating and excessive heat loss from the tissue. This led to thermal damage volumes that are smaller than the cases when the Robin type or the thermal insulation conditions are prescribed. The present study suggests that RFA simulations in the future must take into consideration the choice of the type of electrical and thermal boundary conditions to be prescribed in the case where the tumour is located near to the liver boundary.
The effects of the no-touch gap on the no-touch bipolar radiofrequency ablation treatment of liver cancer : a numerical study using a two compartment model
- Authors: Yap, Shelley , Cheong, Jason , Foo, Ji , Ooi, Ean Tat , Ooi, Ean Hin
- Date: 2020
- Type: Text , Journal article
- Relation: Applied Mathematical Modelling Vol. 78, no. (2020), p. 134-147
- Full Text: false
- Reviewed:
- Description: The no-touch bipolar radiofrequency ablation (RFA) for cancer treatment is advantageous primarily because of its capability to prevent tumour track seeding (TTS). In this technique, the RF probes are placed at a distance (no-touch gap) away from the tumour boundary. Ideally, the RF probes should be placed sufficiently far from the tumour in order to avoid TTS. However, having a gap that is too large can lead to ineffective ablation. This paper investigates how the selection of the no-touch gap can affect the tissue electrical and thermal responses during the no-touch bipolar RFA treatment. Simulations were carried out on a two compartment model using the finite element method. Results obtained indicated that a gap that is too large may lead to incomplete ablation and failure to achieve significant ablation margin. However, keeping the gap to be too small may not be clinically practical. It was suggested that the incomplete ablation and the insufficient ablation margin observed in some of the cases may require the placement of additional probes around the tumour. The present study stresses on the importance of identifying the optimal no-touch gap that can avoid TTS without compromising the treatment outcome. © 2019 Elsevier Inc.