Flexible operation of CSIRO's post-combustion CO2 capture pilot plant at the AGL Loy Yang power station
- Bui, Mai, Gunawan, Indra, Verheyen, Vincent, Feron, Paul, Meuleman, Erik
- Authors: Bui, Mai , Gunawan, Indra , Verheyen, Vincent , Feron, Paul , Meuleman, Erik
- Date: 2016
- Type: Text , Journal article
- Relation: International Journal of Greenhouse Gas Control Vol. 48, no. (May 2016), p. 188-203
- Full Text:
- Reviewed:
- Description: Flexible operation has the potehtial to significantly improve the economic viability of post-combustion CO2 capture (PCC). However, the impact of disturbances from flexible operation of the PCC process is unclear. The purpose of this study was to investigate the effects of flexible operation in a PCC pilot plant by implementing step-changes for improved dynamic data reliability. The flexible operation campaign was conducted at the CSIRO PCC pilot plant at AGL Loy Yang using monoethanolamine (MEA) absorbent. The pilot plant was operated under a broad range of transient conditions (changing flue gas flow, liquid absorbent flow and steam pressure) to capture the dynamics of a PCC process during flexible operation. The study demonstrated that the dynamics of flue gas flow rate was faster than absorbent flow rate. The greatest CO2 removal% was achieved at the lowest flue gas flow rate or at the highest absorbent flow rate; however, the latter provided improved energy efficiency. The steam pressure parameter could adjust the temperature of all columns simultaneously which can be used to compensate for effects from ambient conditions or heat losses. These results verify the technical feasibility of flexible PCC operation and provide a suitable dataset for dynamic model validation. (C) 2015 Elsevier Ltd. All rights reserved.
- Authors: Bui, Mai , Gunawan, Indra , Verheyen, Vincent , Feron, Paul , Meuleman, Erik
- Date: 2016
- Type: Text , Journal article
- Relation: International Journal of Greenhouse Gas Control Vol. 48, no. (May 2016), p. 188-203
- Full Text:
- Reviewed:
- Description: Flexible operation has the potehtial to significantly improve the economic viability of post-combustion CO2 capture (PCC). However, the impact of disturbances from flexible operation of the PCC process is unclear. The purpose of this study was to investigate the effects of flexible operation in a PCC pilot plant by implementing step-changes for improved dynamic data reliability. The flexible operation campaign was conducted at the CSIRO PCC pilot plant at AGL Loy Yang using monoethanolamine (MEA) absorbent. The pilot plant was operated under a broad range of transient conditions (changing flue gas flow, liquid absorbent flow and steam pressure) to capture the dynamics of a PCC process during flexible operation. The study demonstrated that the dynamics of flue gas flow rate was faster than absorbent flow rate. The greatest CO2 removal% was achieved at the lowest flue gas flow rate or at the highest absorbent flow rate; however, the latter provided improved energy efficiency. The steam pressure parameter could adjust the temperature of all columns simultaneously which can be used to compensate for effects from ambient conditions or heat losses. These results verify the technical feasibility of flexible PCC operation and provide a suitable dataset for dynamic model validation. (C) 2015 Elsevier Ltd. All rights reserved.
Techno-economic evaluation of amine-reclamation technologies and combined CO2/SO2 capture for Australian coal-fired plants
- Garg, Bharti, Haque, Nawshad, Cousins, Ashleigh, Pearson, Pauline, Verheyen, Vincent, Feron, Paul
- Authors: Garg, Bharti , Haque, Nawshad , Cousins, Ashleigh , Pearson, Pauline , Verheyen, Vincent , Feron, Paul
- Date: 2020
- Type: Text , Journal article
- Relation: International Journal of Greenhouse Gas Control Vol. 98, no. (2020), p.
- Full Text:
- Reviewed:
- Description: CSIRO's patented CS-Cap process aims at reducing the costs of amine-based post-combustion capture by combining SO2 and CO2 capture using one absorbent in a single absorber column. By avoiding the need for a separate flue gas desulfurization unit, the process offers potential savings for power plants requiring CO2 capture. High-level cost estimates based on lab and pilot data are presented for two amine reclamation techniques i.e. thermal reclamation and reactive crystallisation. Only regeneration via reactive crystallisation reduces CS-Cap costs below base case FGD/SCR-PCC. Cost estimations suggest a potential reduction of 38–44% in the total plant cost when using the CS-Cap process compared to base case. However, the amine reclaimer operating cost governs the overall cost of the CS-Cap process and is highly sensitive to sulfur content. A 50% reduction is observed when SO2 levels reduce from 700 to 200 ppm. Comparing levelised cost of electricity and CO2 avoided costs for CS-Cap against our base case, low sulfur brown coal has a slight (5–7%) cost advantage; however, confirmation requires pilot data on amine recovery. © 2020
- Authors: Garg, Bharti , Haque, Nawshad , Cousins, Ashleigh , Pearson, Pauline , Verheyen, Vincent , Feron, Paul
- Date: 2020
- Type: Text , Journal article
- Relation: International Journal of Greenhouse Gas Control Vol. 98, no. (2020), p.
- Full Text:
- Reviewed:
- Description: CSIRO's patented CS-Cap process aims at reducing the costs of amine-based post-combustion capture by combining SO2 and CO2 capture using one absorbent in a single absorber column. By avoiding the need for a separate flue gas desulfurization unit, the process offers potential savings for power plants requiring CO2 capture. High-level cost estimates based on lab and pilot data are presented for two amine reclamation techniques i.e. thermal reclamation and reactive crystallisation. Only regeneration via reactive crystallisation reduces CS-Cap costs below base case FGD/SCR-PCC. Cost estimations suggest a potential reduction of 38–44% in the total plant cost when using the CS-Cap process compared to base case. However, the amine reclaimer operating cost governs the overall cost of the CS-Cap process and is highly sensitive to sulfur content. A 50% reduction is observed when SO2 levels reduce from 700 to 200 ppm. Comparing levelised cost of electricity and CO2 avoided costs for CS-Cap against our base case, low sulfur brown coal has a slight (5–7%) cost advantage; however, confirmation requires pilot data on amine recovery. © 2020
- «
- ‹
- 1
- ›
- »