Improving voltage of remote connection using wind-solar farms equipped with new voltage control strategy based on virtual impedance monitoring enabled by IEC 61850 communication
- Authors: Aghanoori, Navid , Masoum, Mohammad , Islam, Syed , Abu-Siada, Ahmed , Nethery, Steven
- Date: 2019
- Type: Text , Journal article
- Relation: IET Generation, Transmission and Distribution Vol. 13, no. 11 (2019), p. 2112-2122
- Full Text: false
- Reviewed:
- Description: This study explores how the voltage control of a remote part of the utility gird can be improved using more sophisticated voltage control on wind-solar farms equipped with fast communication platforms. The idea is to make renewable plant the master voltage controller during large disturbance events in the grid. This is done by proposing an enhanced voltage droop control strategy based on instantaneous reactive power consumption by monitoring the virtual impedance of the point of connection using a new customised data class model of IEC 61850 communication protocol. The conventional centralised voltage droop control strategy and the proposed instantaneous direct voltage control method are both implemented on the White Rock Solar Wind Farm in NSW, Australia and their performances are compared using both MATLAB Simulink simulations under 5% voltage step disturbances, single-phase-to-ground and three-phase-to-ground faults as well as some tests conducted in the field.
Investigation of microgrid instability caused by time delay
- Authors: Aghanoori, Navid , Masoum, Mohammad , Islam, Syed , Nethery, Steven
- Date: 2017
- Type: Text , Conference proceedings , Conference paper
- Relation: 10th International Conference on Electrical and Electronics Engineering, ELECO 2017; Bursa, Turkey; 29th-2nd December 2017 Vol. 2018, p. 105-110
- Full Text:
- Reviewed:
- Description: This paper investigates the impact of time delay in the control of a grid-connected microgrid with renewable energy resources. The considered microgrid has a critical load that needs to be powered and protected in the event of grid voltage disturbance while the microgrid maintains connection to the grid. Three case studies are performed considering three different time delays to indicate the advantages of fast communication system in the performance of renewable microgrids. Detailed simulation results illustrate that the proposed communication system using IEC 61850 substation automation standard provides better voltage and current quality to the critical local load with larger phase and gain margins while keeping the microgid connected to main grid.